High-performance liquid chromatographic method with amperometric detection employing boron-doped diamond electrode for the determination of sildenafil, vardenafil and their main metabolites in plasma

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F11%3A33117924" target="_blank" >RIV/61989592:15310/11:33117924 - isvavai.cz</a>

  • Alternative codes found

    RIV/70883521:28610/11:43865692

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.chroma.2011.09.001" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2011.09.001</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.chroma.2011.09.001" target="_blank" >10.1016/j.chroma.2011.09.001</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    High-performance liquid chromatographic method with amperometric detection employing boron-doped diamond electrode for the determination of sildenafil, vardenafil and their main metabolites in plasma

  • Original language description

    A simple, fast and sensitive HPLC method with electrochemical detection employing boron-doped diamond electrode (BDD) for the determination of sildenafil (Viagra (TM)), vardenafil (Levitra (TM)) and their main metabolites, N-desmethyl sildenafil and N-desethyl vardenafil in human plasma is presented. The assay involved drug extraction by tert-butyl methyl ether and isocratic reversed-phase liquid chromatography with amperometric detection. Complete separation of all analytes was achieved within 12 min.The mobile phase consisted of 20 mM sodium dihydrogen phosphate with 40 mM sodium perchlorate/acetonitrile (70:30, v/v), pH 3.5. The electrode working potential was +1520 mV (vs. Pd/H(2)). Calibration curves were linear over the concentration range of 10-400 ng mL(-1) Phloretin was used as an internal standard. The limits of detection (LOD) and quantification (LOQ) for the studied analytes were within the range of 2-4 ng mL(-1) and 7.0-13.4 ng mL(-1), respectively. The developed method w

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/ED2.1.00%2F03.0111" target="_blank" >ED2.1.00/03.0111: Centre of Polymer Systems</a><br>

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Chromatography A

  • ISSN

    0021-9673

  • e-ISSN

  • Volume of the periodical

    1218

  • Issue of the periodical within the volume

    44

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    7996-8001

  • UT code for WoS article

    000296549000012

  • EID of the result in the Scopus database