Evaluation of new mixed-mode UHPLC stationary phases and the importance of stationary phase choice when using low ionic-strength mobile phase additives
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F12%3A10124897" target="_blank" >RIV/00216208:11160/12:10124897 - isvavai.cz</a>
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S0039914012000951" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0039914012000951</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2012.01.054" target="_blank" >10.1016/j.talanta.2012.01.054</a>
Alternative languages
Result language
angličtina
Original language name
Evaluation of new mixed-mode UHPLC stationary phases and the importance of stationary phase choice when using low ionic-strength mobile phase additives
Original language description
In this study, the selectivity, retention properties, peak shape and loading capacity for bases were practically evaluated using two UHPLC mixed-mode hybrid CSH stationary phases modified by C18 or Phenyl group. The data were compared with the data obtained on other UHPLC hybrid stationary phases (BEH C18, BEH C8, BEH Phenyl and BEH Shield RP18) at both basic and acidic conditions using conventional HPLC buffers (50 mM ammonium formate/acetate) as well as low ionic-strength additives such as, e.g. 0.1-0.01% formic/acetic acid and 1 mM solution of ammonium formate/acetate, which are widely used in LC-MS applications. Ten pharmaceutically important compounds encompassing acids, bases and neutral were included into the study. Due to properties of CSH sorbent (which possess positively charged surface besides RP group), much improved peak shapes and weaker retention was obtained for bases even at very low concentration of acidic additives. Such conditions are ideally suited for LC-MS analys
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Talanta
ISSN
0039-9140
e-ISSN
—
Volume of the periodical
93
Issue of the periodical within the volume
1
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
7
Pages from-to
99-105
UT code for WoS article
000303305700014
EID of the result in the Scopus database
—