All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Mass Spectrometric and Contactless Conductivity Detection Approaches in the Determination of Muscle Relaxants by Capillary Electrophoresis

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F13%3A10145768" target="_blank" >RIV/00216208:11160/13:10145768 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.tandfonline.com/doi/full/10.1080/00032719.2013.798798" target="_blank" >http://www.tandfonline.com/doi/full/10.1080/00032719.2013.798798</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1080/00032719.2013.798798" target="_blank" >10.1080/00032719.2013.798798</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Mass Spectrometric and Contactless Conductivity Detection Approaches in the Determination of Muscle Relaxants by Capillary Electrophoresis

  • Original language description

    Novel and rapid capillary electrophoresis-coupled tandem mass spectrometry (CE-MS/MS) and capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C(4)D) methods have been developed for the separation and determination of three neuromuscular blocking agents: pancuronium, vecuronium, and rocuronium. In both cases, the separation was conducted in background electrolytes based on acidic acetate-ammonium buffers to avoid possible decomposition of the analytes that are knownto be unstable in alkaline media. Baseline resolution of the analytes was achieved in the presence of modified gamma-cyclodextrin by CE with C(4)D detection. The two detection techniques were compared with regard to analytical figures of merit includinglinear dynamic range, limit of detection, limit of quantification, precision, and accuracy. The calibration curves showed good linearity for both detection methods examined (characterized by r(2) }= 0.9908). The LODs of the CE-MS/MS and

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/EE2.3.30.0061" target="_blank" >EE2.3.30.0061: Increasing of the R&D capacity at Charles University through new positions for graduates of doctoral studies</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytical Letters

  • ISSN

    0003-2719

  • e-ISSN

  • Volume of the periodical

    46

  • Issue of the periodical within the volume

    14

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    15

  • Pages from-to

    2165-2179

  • UT code for WoS article

    000323997100003

  • EID of the result in the Scopus database