Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F13%3A10145776" target="_blank" >RIV/00216208:11160/13:10145776 - isvavai.cz</a>
Result on the web
<a href="http://link.springer.com/article/10.1007/s12161-013-9573-0/fulltext.html" target="_blank" >http://link.springer.com/article/10.1007/s12161-013-9573-0/fulltext.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s12161-013-9573-0" target="_blank" >10.1007/s12161-013-9573-0</a>
Alternative languages
Result language
angličtina
Original language name
Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis
Original language description
Capillary electrophoretic method suitable for the assay of citrus flavonoids (hesperidin, diosmin, and rutin), troxerutin, and ascorbic acid in food supplements and pharmaceutical formulations was devised and validated. The separation was carried out at25 kV in uncoated fused-silica capillary (50 mu m i.d.; total length, 32 cm (21 cm to detector); and spectrophotometric detection at 280 nm) maintained at 25 A degrees C with 40 mM sodium tetraborate buffer of pH 9.5 containing 25 % (v/v) of methanol asthe background electrolyte. The samples were injected hydrodynamically (50 mbar, 6 s). The calibration curves were linear (correlation coefficients r = 0.9994-0.9998) for 0.05-0.50 mg/mL of hesperidin, diosmin, rutin, and troxerutin and 0.10-1.00 mg/mL of ascorbic acid when using cinnamic acid (0.05 mg/mL) as internal standard (IS). The LOQ values (S/N = 10) ranged between 0.02 and 0.04 mg/mL of an analyte. The intra- and interday repeatability of migration times and corrected peak areas
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Food Analytical Methods
ISSN
1936-9751
e-ISSN
—
Volume of the periodical
6
Issue of the periodical within the volume
6
Country of publishing house
GB - UNITED KINGDOM
Number of pages
7
Pages from-to
1561-1567
UT code for WoS article
000326691300009
EID of the result in the Scopus database
—