All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F13%3A10145776" target="_blank" >RIV/00216208:11160/13:10145776 - isvavai.cz</a>

  • Result on the web

    <a href="http://link.springer.com/article/10.1007/s12161-013-9573-0/fulltext.html" target="_blank" >http://link.springer.com/article/10.1007/s12161-013-9573-0/fulltext.html</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s12161-013-9573-0" target="_blank" >10.1007/s12161-013-9573-0</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis

  • Original language description

    Capillary electrophoretic method suitable for the assay of citrus flavonoids (hesperidin, diosmin, and rutin), troxerutin, and ascorbic acid in food supplements and pharmaceutical formulations was devised and validated. The separation was carried out at25 kV in uncoated fused-silica capillary (50 mu m i.d.; total length, 32 cm (21 cm to detector); and spectrophotometric detection at 280 nm) maintained at 25 A degrees C with 40 mM sodium tetraborate buffer of pH 9.5 containing 25 % (v/v) of methanol asthe background electrolyte. The samples were injected hydrodynamically (50 mbar, 6 s). The calibration curves were linear (correlation coefficients r = 0.9994-0.9998) for 0.05-0.50 mg/mL of hesperidin, diosmin, rutin, and troxerutin and 0.10-1.00 mg/mL of ascorbic acid when using cinnamic acid (0.05 mg/mL) as internal standard (IS). The LOQ values (S/N = 10) ranged between 0.02 and 0.04 mg/mL of an analyte. The intra- and interday repeatability of migration times and corrected peak areas

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Food Analytical Methods

  • ISSN

    1936-9751

  • e-ISSN

  • Volume of the periodical

    6

  • Issue of the periodical within the volume

    6

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    7

  • Pages from-to

    1561-1567

  • UT code for WoS article

    000326691300009

  • EID of the result in the Scopus database