All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F13%3A10146049" target="_blank" >RIV/00216208:11160/13:10146049 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.sciencedirect.com/science/article/pii/S1570023213000160" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1570023213000160</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.jchromb.2012.12.032" target="_blank" >10.1016/j.jchromb.2012.12.032</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters

  • Original language description

    In this paper two fast and highly sensitive ultra-high performance liquid chromatography (UHPLC) methods for the determination of tetracycline antibiotics (oxytetracycline, tetracycline, doxycycline, demeclocycline, chlortetracycline, minocycline and degradation product epitetracycline) in surface waters have been developed using fluorescence (FL) and mass spectrometry (MS) detection. ACQUITY UPLC BEH C8 and ACQUITY CSH C18 columns were employed for FL and MS detection, respectively, both packed with 1.7 mu m particles. Mixed-mode separation mechanism of CSH (charged surface technology) sorbent was found particularly useful in analysis of TCs, which possess problematic amphoteric structures. The FL methodology was based on chelation of tetracyclines with calcium ions to perform on-column derivatisation. The developed methods were compared in the terms of validation parameters including linearity, sensitivity, precision and accuracy. The linearity range for FL detection was within 7 ng

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/KJB601100901" target="_blank" >KJB601100901: MONITORING OF PHARMACEUTICALS IN WASTEWATERS USING UPLC-MS/MS TECHNIQUE</a><br>

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences

  • ISSN

    1570-0232

  • e-ISSN

  • Volume of the periodical

    927

  • Issue of the periodical within the volume

    May

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    8

  • Pages from-to

    201-208

  • UT code for WoS article

    000318668000020

  • EID of the result in the Scopus database