How to address the sample preparation of hydrophilic compounds: Determination of entecavir in plasma and plasma ultrafiltrate with novel extraction sorbents
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F14%3A10146060" target="_blank" >RIV/00216208:11160/14:10146060 - isvavai.cz</a>
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S073170851300397X" target="_blank" >http://www.sciencedirect.com/science/article/pii/S073170851300397X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jpba.2013.08.034" target="_blank" >10.1016/j.jpba.2013.08.034</a>
Alternative languages
Result language
angličtina
Original language name
How to address the sample preparation of hydrophilic compounds: Determination of entecavir in plasma and plasma ultrafiltrate with novel extraction sorbents
Original language description
Two fast, simple, selective and economical sample preparation methods for the determination of entecavir in biological materials available at low amounts are reported. The choice of optimal extraction techniques was performed with regard to analyte hydrophilicity, sample volumes, selectivity, method recovery and rapidity. The compatibility of the eluate with the hydrophilic interaction chromatography (HILIC) mobile phase was crucial to allow the elimination of the evaporation and reconstitution steps and to obtain acceptable peak shapes. Different types of sorbents were employed for the extraction of two biological materials (plasma and plasma ultrafiltrate). The mixed-mode polymeric sorbent MCX was chosen as a suitable one for the solid phase extraction (SPE) of plasma samples. The analytes were eluted with 1 ml of the mixture of 5% ammonium hydroxide in ACN:water (95:5). Protein precipitation (PP) with 1 ml of ACN was used to remove proteins from 500 RI of plasma sample prior to SPE
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Pharmaceutical and Biomedical Analysis
ISSN
0731-7085
e-ISSN
—
Volume of the periodical
88
Issue of the periodical within the volume
January
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
8
Pages from-to
337-344
UT code for WoS article
000329532800045
EID of the result in the Scopus database
—