All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F14%3A10282008" target="_blank" >RIV/00216208:11160/14:10282008 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.sciencedirect.com/science/article/pii/S0039914014005190" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0039914014005190</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2014.06.063" target="_blank" >10.1016/j.talanta.2014.06.063</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay

  • Original language description

    A simple and rapid method for the determination of the methylene blue active substances assay based on in-syringe automation of magnetic stirring-assisted dispersive liquid-liquid microextraction was developed. The proposed method proved to be valid forthe determination of anionic surfactant in waste, pond, well, tap, and drinking water samples. Sample mixing with reagents, extraction and phase separation were performed within the syringe of an automated syringe pump containing a magnetic stirring barfor homogenization and solvent dispersion. The syringe module was used upside-down to enable the use of chloroform as an extraction solvent of higher density than water. The calibration was found to be linear up to 0.3 mg/L using only 200 mu L of solventand 4 mL of sample. The limits of detection (3 sigma) and quantification (10 sigma) were 7.0 mu g/L and 22 mu g/L, respectively. The relative standard deviation for 10 replicate determinations of 0.1 mg/L SBDS was below 3%. Concentration

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/EE2.3.30.0022" target="_blank" >EE2.3.30.0022: Support of establishment, development, and mobility of quality research teams at the Charles University</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

  • Volume of the periodical

    130

  • Issue of the periodical within the volume

    December

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    6

  • Pages from-to

    555-560

  • UT code for WoS article

    000341897800075

  • EID of the result in the Scopus database