Lab-In-Syringe for automated double-stage sample preparation by coupling salting out liquid-liquid extraction with online solid-phase extraction and liquid chromatographic separation for sulfonamide antibiotics from urine
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F21%3A10434540" target="_blank" >RIV/00216208:11160/21:10434540 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=c4PdXC3-5f" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=c4PdXC3-5f</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2020.121427" target="_blank" >10.1016/j.talanta.2020.121427</a>
Alternative languages
Result language
angličtina
Original language name
Lab-In-Syringe for automated double-stage sample preparation by coupling salting out liquid-liquid extraction with online solid-phase extraction and liquid chromatographic separation for sulfonamide antibiotics from urine
Original language description
A double-stage Lab-In-Syringe automated extraction procedure coupled online to HPLC for the determination of four sulfonamides in urine has been developed. Our method is based on homogeneous liquid-liquid extraction at pH 3 using water-miscible acetonitrile with induction of phase separation by the addition of a saturated solution of kosmotropic salts MgSO4 and NaCl. The procedure allowed extraction of the moderately polar model analytes and the use of a solvent that is compatible with the used separation technique. The automated sample preparation system based on the stirring-assisted Lab-In-Syringe approach was coupled on-line with HPLC-UV for the subsequent separation of the sulfonamide antibiotics. To improve both preconcentration factor and extract cleanup, the analytes were trapped at pH 10 in an anion-exchange resin cartridge integrated into the HPLC injection loop thus achieving a double-stage sample clean-up. Analytes were eluted using an acidic HPLC mobile phase in gradient elution mode. Running the analytes separation and the two-step preparation of the following sample in parallel reduced the total time of analysis to mere 13.5 min. Limits of detection ranged from 5.0 to 7.5 mu g/L with linear working ranges of 50-5000 mu g/L (r(2) > 0.9997) and RSD <= 5% (n = 6) at a concentration level of 50 mu g/L. Average recovery values were 102.7 +/- 7.4% after spiking of urine with sulfonamides at concentrations of 2.5 and 5 mg/L followed by 5 times dilution. To the best of our knowledge, the use of Lab-In-Syringe for the automation of coupled homogeneous liquid-liquid extraction and SPE for preparation of the complex matrices suitable for separation techniques is here presented for the first time.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30104 - Pharmacology and pharmacy
Result continuities
Project
<a href="/en/project/EF15_003%2F0000465" target="_blank" >EF15_003/0000465: Establishment of Specialized Team for Advanced Research on Separation Science</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Talanta
ISSN
0039-9140
e-ISSN
—
Volume of the periodical
221
Issue of the periodical within the volume
January
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
8
Pages from-to
121427
UT code for WoS article
000579910600016
EID of the result in the Scopus database
2-s2.0-85088900329