All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F14%3A10282243" target="_blank" >RIV/00216208:11160/14:10282243 - isvavai.cz</a>

  • Result on the web

    <a href="http://pubs.rsc.org/en/content/articlehtml/2014/ay/c3ay42200c" target="_blank" >http://pubs.rsc.org/en/content/articlehtml/2014/ay/c3ay42200c</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1039/c3ay42200c" target="_blank" >10.1039/c3ay42200c</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine

  • Original language description

    A new gradient reversed-phase HPLC method with pre-column derivatization was developed and validated for simultaneous determination of reduced glutathione, carnosine and taurine in new pharmaceutical eye drops. Chromatographic separation was achieved with a fused core analytical column Supelco Ascentis Express C18 (100 mm x 4.6 mm, 2.7 mu m). A 30 mM triethylamine in acetonitrile with 30 mM triethylamine aqueous solution (pH 2.5, adjusted with glacial acetic acid) was used in a gradient elution mode ata flow rate of 0.8 mL min(-1). The column temperature was maintained at 30 degrees C, the injection volume of the derivatized sample was 5 mu L and the detection wavelength was 375 nm. The tested validation parameters included system suitability, accuracy, precision, linearity, LOD, LOQ and sample solution stability. The standard calibration curves showed good linearity with correlation coefficients r > 0.997 for all compounds. The mean percentage recoveries obtained for reduced glutathi

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/EE2.3.20.0235" target="_blank" >EE2.3.20.0235: Establishment of Research Team Focused on Experimental and Applied Biopharmacy</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytical Methods

  • ISSN

    1759-9660

  • e-ISSN

  • Volume of the periodical

    6

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    7

  • Pages from-to

    1475-1481

  • UT code for WoS article

    000332129500030

  • EID of the result in the Scopus database