An on-line SPE-HPLC method for effective sample preconcentration and determination of fenoxycarb and cis, trans-permethrin in surface waters
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F15%3A10312552" target="_blank" >RIV/00216208:11160/15:10312552 - isvavai.cz</a>
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S003991401500315X" target="_blank" >http://www.sciencedirect.com/science/article/pii/S003991401500315X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2015.04.066" target="_blank" >10.1016/j.talanta.2015.04.066</a>
Alternative languages
Result language
angličtina
Original language name
An on-line SPE-HPLC method for effective sample preconcentration and determination of fenoxycarb and cis, trans-permethrin in surface waters
Original language description
A new on-line SPE-HPLC method using fused-core columns for on-line solid phase extraction and large volume sample injection for increasing the sensitivity of detection was developed for the determination of insecticides fenoxycarb and cis-, trans-permethrin in surface waters. The separation was carried out on fused-core column Phenyl-Hexyl (100 x 4.6 mm), particle size 2.7 mu m with mobile phase acetonitrile: water in gradient mode at flow rate 1.0 mL min(-1), column temperature 45 degrees C. Large volume sample injection (1500 mu L) to the extraction dimension using short precolumn Ascentis Express RP C-18 (5 x 4.6 mm); fused-core particle size 2.7 mu m allowed effective sample preconcentration and efficient ballast sample matrix removal. The washingmobile phase consisting of a mixture of acetonitrile:water; 30:70, (v/v) was pumped at flow rate of 0.5 mL min(-1) through the extraction precolumn to the waste. Time of the valve switch for transferring the preconcentrated sample zone fr
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GA15-10781S" target="_blank" >GA15-10781S: On-line hyphenation of automated extraction processes with liquid chromatography for complete sample analysis</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Talanta
ISSN
0039-9140
e-ISSN
—
Volume of the periodical
142
Issue of the periodical within the volume
September
Country of publishing house
GB - UNITED KINGDOM
Number of pages
7
Pages from-to
124-130
UT code for WoS article
000356997700017
EID of the result in the Scopus database
2-s2.0-84928949663