Micellar electrokinetic chromatography with short-end injection for rapid separation and simultaneous determination of aesculin, aesculetin, and phenylephrine in pharmaceutical preparations

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F15%3A10317293" target="_blank" >RIV/00216208:11160/15:10317293 - isvavai.cz</a>

  • Result on the web

    <a href="http://onlinelibrary.wiley.com/doi/10.1002/elps.201500215/full" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/elps.201500215/full</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/elps.201500215" target="_blank" >10.1002/elps.201500215</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Micellar electrokinetic chromatography with short-end injection for rapid separation and simultaneous determination of aesculin, aesculetin, and phenylephrine in pharmaceutical preparations

  • Original language description

    A fast micellar electrokinetic chromatography (MEKC) method for simultaneous assay of aesculin, aesculetin, and phenylephrine was developed and validated. The separation was carried out in a fused-silica capillary (50 mu m id, total length 64.5 cm, effective length 8.5 cm) with UV detection at 210 nm, temperature 25 degrees C and separation voltage -25 kV. The samples were loaded hydrodynamically at a pressure of -50 mbar for 6 s. The background electrolyte of pH 8.6 contained 20 mM boric acid, 60 mM SDS, and 5% (v/v) of methanol. The calibration curves were linear in the range 10-500 mu g/mL for aesculin and aesculetin and 12.5-625 mu g/mL for phenylephrine. The RSD values of corrected peak areas were 0.6-1.2% (n = 6) when determining 0.2 mg/mL of aesculin and aesculetin and 0.25 mg/mL of phenylephrine in prepared standard mixtures. The method was successfully applied to the assay of aesculin and phenylephrine in a pharmaceutical preparation (RSD = 1.9-2.0%; n = 3) and the robustness

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/EE2.3.30.0061" target="_blank" >EE2.3.30.0061: Increasing of the R&D capacity at Charles University through new positions for graduates of doctoral studies</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Electrophoresis

  • ISSN

    0173-0835

  • e-ISSN

  • Volume of the periodical

    36

  • Issue of the periodical within the volume

    21

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    8

  • Pages from-to

    2754-2761

  • UT code for WoS article

    000365620500015

  • EID of the result in the Scopus database

    2-s2.0-84947866754