All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Fast separation of red colorants in beverages using cyano monolithic column in Sequential Injection Chromatography

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F17%3A10364766" target="_blank" >RIV/00216208:11160/17:10364766 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.sciencedirect.com/science/article/pii/S0026265X16302971" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0026265X16302971</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.microc.2016.10.022" target="_blank" >10.1016/j.microc.2016.10.022</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Fast separation of red colorants in beverages using cyano monolithic column in Sequential Injection Chromatography

  • Original language description

    Flexible medium-pressure Sequential Injection Chromatography (SIC) flow manifold was used for development of a fast green chromatography method. The article presents novel use of a cyano monolithic column (Merck Chromolith 50 mm x 4.6 mm) for a separation of three water soluble colorants (carmoisine, Ponceau 4R and red 2G), aiming the extension of the SIC separation capabilities for polar analytes. The separation was performed in a gradient elution mode with changing concentration (0.05-0.005% v/v) of ammonium phosphate at pH 6.0 as a mobile phase. No organic modifier was used in mobile phase, thus the green chromatography rules were fulfilled. The vis spectrophotometric detection was set at 500 nm. High performance of the separation with the cyano monolithic column was described and discussed (peak capacities 6.67-10.94, peak symmetries 1.11-1.50, resolutions &gt;= 2.78 and time for one analysis 3.15 min). The method was represented by analytical parameters - LODs of 0.45 mg L-1, a LOQs of 1.5 mg L-1 and calibration range of 1.5-60.0 mg L-1 (r &gt; 0.997) for all analytes, and a method repeatability at 10 mg L-1 of RSD &lt;= 2.69% (n = 5) and system precision of RSD &lt; 1.55% (n = 6). The developed method was used for determination of carmoisine and Ponceau 4R in red coloured beverages with red 2G as an internal standard. The results confirmed benefits of extended chromatographic selectivity of cyano monolithic column in the SIC.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30104 - Pharmacology and pharmacy

Result continuities

  • Project

    <a href="/en/project/GA15-10781S" target="_blank" >GA15-10781S: On-line hyphenation of automated extraction processes with liquid chromatography for complete sample analysis</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Microchemical Journal

  • ISSN

    0026-265X

  • e-ISSN

  • Volume of the periodical

    130

  • Issue of the periodical within the volume

    January

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    384-389

  • UT code for WoS article

    000390072400054

  • EID of the result in the Scopus database

    2-s2.0-84994017856