Fast separation of red colorants in beverages using cyano monolithic column in Sequential Injection Chromatography
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F17%3A10364766" target="_blank" >RIV/00216208:11160/17:10364766 - isvavai.cz</a>
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S0026265X16302971" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0026265X16302971</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.microc.2016.10.022" target="_blank" >10.1016/j.microc.2016.10.022</a>
Alternative languages
Result language
angličtina
Original language name
Fast separation of red colorants in beverages using cyano monolithic column in Sequential Injection Chromatography
Original language description
Flexible medium-pressure Sequential Injection Chromatography (SIC) flow manifold was used for development of a fast green chromatography method. The article presents novel use of a cyano monolithic column (Merck Chromolith 50 mm x 4.6 mm) for a separation of three water soluble colorants (carmoisine, Ponceau 4R and red 2G), aiming the extension of the SIC separation capabilities for polar analytes. The separation was performed in a gradient elution mode with changing concentration (0.05-0.005% v/v) of ammonium phosphate at pH 6.0 as a mobile phase. No organic modifier was used in mobile phase, thus the green chromatography rules were fulfilled. The vis spectrophotometric detection was set at 500 nm. High performance of the separation with the cyano monolithic column was described and discussed (peak capacities 6.67-10.94, peak symmetries 1.11-1.50, resolutions >= 2.78 and time for one analysis 3.15 min). The method was represented by analytical parameters - LODs of 0.45 mg L-1, a LOQs of 1.5 mg L-1 and calibration range of 1.5-60.0 mg L-1 (r > 0.997) for all analytes, and a method repeatability at 10 mg L-1 of RSD <= 2.69% (n = 5) and system precision of RSD < 1.55% (n = 6). The developed method was used for determination of carmoisine and Ponceau 4R in red coloured beverages with red 2G as an internal standard. The results confirmed benefits of extended chromatographic selectivity of cyano monolithic column in the SIC.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30104 - Pharmacology and pharmacy
Result continuities
Project
<a href="/en/project/GA15-10781S" target="_blank" >GA15-10781S: On-line hyphenation of automated extraction processes with liquid chromatography for complete sample analysis</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Microchemical Journal
ISSN
0026-265X
e-ISSN
—
Volume of the periodical
130
Issue of the periodical within the volume
January
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
6
Pages from-to
384-389
UT code for WoS article
000390072400054
EID of the result in the Scopus database