New generation of sequential injection chromatography: Great enhancement of capabilities of separation using flow analysis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F19%3A10399617" target="_blank" >RIV/00216208:11160/19:10399617 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=lO669h3goe" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=lO669h3goe</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2019.05.108" target="_blank" >10.1016/j.talanta.2019.05.108</a>
Alternative languages
Result language
angličtina
Original language name
New generation of sequential injection chromatography: Great enhancement of capabilities of separation using flow analysis
Original language description
Since its inception, sequential injection chromatography (SIC) has evolved through several stages. Key moments including introduction of the novel technique combining sequential injection analysis and monolithic column, the first generation of commercial SIC system employing robust pump, the utilization of columns packed with fused-core particles, the on-line hyphenation of extraction and separation steps in SIC, are now followed by the second generation of commercial SIC system employing stainless steel syringe pump and parts optimized for chromatographic separation. The key developments always mean acceleration of the evolution by opening new avenues and reduction of compromises in automated analytical methods based on the flow analysis. The updates, new features, and prospects of the novel instrument are described and discussed on perspective of the method developed for extraction and separation of selected phenolic acids (gallic, protocatechuic, caffeic, p-coumaric and ferulic). The method hyphenates miniaturized on-line solid phase extraction using strong anion exchange sorbent in commercial cartridge for HPLC (20 x 1 mm) and liquid chromatography using chromatographic column (C18 50 x 4.6 mm, 5 mu m particles) packed with fused-core particles in the SIC manifold. The separation in gradient mode used acetonitrile: aqueous formic acid pH 2.0 mobile phase and spectrophotometric detection at 270, 300, and 320 nm. Injected sample volumes were 200 and 500 mu L. The performance of the extraction step was characterized by the recovery 94.0-107.8%, enrichment factors about 20 or 50, and the separation by peak capacities 13-34, peak symmetries 1.17-1.64, and resolutions 0.82-3.75). While using a sample volume of 200 mu L, our method was characterized by the following validation parameters: LODs of 0.0075-0.03 mg L-1, LOQs of 0.025-0.10 mg L-1, calibration ranges 0.025-2.50 mg L-1 (r > 0.999), repeatability of signal at 0.50 mg L-1 of RSD <= 1.46% (n = 6), and overall time of analysis 7.1 min. The results including pilot analysis of white and red wines demonstrated the capability of novel SIC instrument to enable fast, selective, and sensitive analysis.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
<a href="/en/project/EF15_003%2F0000465" target="_blank" >EF15_003/0000465: Establishment of Specialized Team for Advanced Research on Separation Science</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Talanta
ISSN
0039-9140
e-ISSN
—
Volume of the periodical
204
Issue of the periodical within the volume
November
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
6
Pages from-to
272-277
UT code for WoS article
000480664200032
EID of the result in the Scopus database
2-s2.0-85066834923