UHPLC coupled with charged aerosol detector for rapid separation of steviol glycosides in commercial sweeteners and extract of Stevia rebaudiana
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F22%3A10445416" target="_blank" >RIV/00216208:11160/22:10445416 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=W0uHHar4vE" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=W0uHHar4vE</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jpba.2021.114398" target="_blank" >10.1016/j.jpba.2021.114398</a>
Alternative languages
Result language
angličtina
Original language name
UHPLC coupled with charged aerosol detector for rapid separation of steviol glycosides in commercial sweeteners and extract of Stevia rebaudiana
Original language description
Natural sweeteners are in high demand as a part of a healthy lifestyle. Among them, sweeteners with decreased caloric value and suitability for diabetes patients are most requested. Extension in their consumption extends the need for their quality control. A fast gradient UHPLC coupled with charged aerosol detection enabling quantitation of stevioside, rebaudioside A-D, and steviolbioside in commercial sweeteners and Stevia rebaudiana plant extracts has been developed. The method was developed to achieve high efficiency, simplicity, versatility, and low solvent consumption. All steviol glycosides were baseline-separated in less than 4 min with a total run time of 7 min. Buffer-free eluents were used in the separations and only 2.45 mL solvent were needed per analysis. The Luna Omega Polar column featuring polar modification of the C18 stationary phase was employed with mobile phases composed of water and acetonitrile for the excellent separation of polar steviol glycosides. The flow rate of the mobile phase 0.35 mL/min, column temperature 50 degrees C and injection volume 2 mu L were used. Critical pair of glycosides, stevioside and rebaudioside A, were baseline separated with a resolution of 2.41. The universal charged aerosol detector allowed quantitation of steviol glycosides with a limit of detection and quantitation 0.15 and 0.5 mu g/mL, respectively. Method intra-day precision was less than 2% (RSD), and the recovery was 89.6-105.0% and 93.8-111.4% for plant material and sweetener tablets, respectively. The quantity of steviol glycosides in three out of four commercial sweeteners was 3.0-12.3% higher than declared. The content was about 12.4% less than declared in one sample. But the difference from the labeled content corresponded to trueness and precision of the developed method together with variability of sweeteners production. The most abundant glycoside detected in sweeteners was stevioside followed by rebaudioside A. A leaf-to-stem ratio describing the dominant accumulation of steviol glycosides in leaves affected the differences in the amount of steviol glycosides among plant samples.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30104 - Pharmacology and pharmacy
Result continuities
Project
<a href="/en/project/EF16_019%2F0000841" target="_blank" >EF16_019/0000841: Efficiency and safety improvement of current drugs and nutraceuticals: advanced methods - new challenges</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Pharmaceutical and Biomedical Analysis
ISSN
0731-7085
e-ISSN
1873-264X
Volume of the periodical
207
Issue of the periodical within the volume
January
Country of publishing house
GB - UNITED KINGDOM
Number of pages
8
Pages from-to
114398
UT code for WoS article
000706129700002
EID of the result in the Scopus database
2-s2.0-85116527193