Large-volume sample stacking for in vivo monitoring of trace levels of gamma-aminobutyric acid, glycine and glutamate in microdialysates of periaqueductal gray matter by capillary electrophoresis with contactless conductivity detection

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F13%3A10144149" target="_blank" >RIV/00216208:11310/13:10144149 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11120/13:43907478

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.chroma.2013.06.019" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2013.06.019</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.chroma.2013.06.019" target="_blank" >10.1016/j.chroma.2013.06.019</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Large-volume sample stacking for in vivo monitoring of trace levels of gamma-aminobutyric acid, glycine and glutamate in microdialysates of periaqueductal gray matter by capillary electrophoresis with contactless conductivity detection

  • Original language description

    A new variant of large-volume sample stacking injection (LVSS) was used in the capillary electrophoresis with capacitively coupled contactless conductivity detection (CE/(CD)-D-4) determination of the neurotransmitters gamma-aminobutyric acid (GABA), glycine (Gly) and glutamate (Glu) in microdialysates of periaqueductal gray matter (PAG). The separation capillary was filled to 98% from the injection side with a sample of microdialysate in acetonitrile. Simultaneously with turning on the separation voltage, the sample zone was forced out by the background electrolyte by increasing the pressure in the terminal capillary outlet vessel. As a consequence of the stacking effect, the analyte was concentrated from the large sample volume into a narrow zone atthe sample/background electrolyte boundary close to the injection end of the capillary. Under these conditions, LOD values of 9, 10 and 15 nM were determined in the model samples for GABA, Gly and Glu, respectively; RSD equalled 0.5% for

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Chromatography A

  • ISSN

    0021-9673

  • e-ISSN

  • Volume of the periodical

    1303

  • Issue of the periodical within the volume

    Neuveden

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    94-99

  • UT code for WoS article

    000322562200012

  • EID of the result in the Scopus database