New flow-through coulometric detector with renewable working electrode material for flow injection analysis and HPLC
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10293509" target="_blank" >RIV/00216208:11310/15:10293509 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.electacta.2014.12.091" target="_blank" >http://dx.doi.org/10.1016/j.electacta.2014.12.091</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.electacta.2014.12.091" target="_blank" >10.1016/j.electacta.2014.12.091</a>
Alternative languages
Result language
angličtina
Original language name
New flow-through coulometric detector with renewable working electrode material for flow injection analysis and HPLC
Original language description
Newly developed flow-through coulometric detector with renewable working material of glassy carbon microbeads was fabricated and its basic electrochemical parameters were studied by flow injection analysis using potassium ferrocyanide and hydroquinone asprobes. Main advantage of the detector is its simple construction while maintaining good electrochemical parameters and high conversion degree. Practical application of the detector was proved by the development of new HPLC and FIA method of thymol andsulfamethizole determination in pharmaceutical preparations. Optimal determination conditions were found and calibration dependences were measured. A value of quantification limit 0.97 mu mol L (1) for thymol and 0.040 mu mol L (1) for sulfamethizole were obtained. Newly developed methods were used for determination of the studied compounds in pharmaceutical preparations. HPLC with spectrophotometric detection was used as a comparative method; results from both methods were in good agree
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Center of novel approaches to bioanalysis and molecular diagnostics</a><br>
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Electrochimica Acta
ISSN
0013-4686
e-ISSN
—
Volume of the periodical
154
Issue of the periodical within the volume
February
Country of publishing house
GB - UNITED KINGDOM
Number of pages
397
Pages from-to
397-403
UT code for WoS article
000349546500052
EID of the result in the Scopus database
2-s2.0-84919807907