Determination of bromhexine at a glassy carbon paste electrode using differential pulse voltammetry and flow injection analysis with amperometric detection
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10312012" target="_blank" >RIV/00216208:11310/15:10312012 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1007/s00706-015-1469-9" target="_blank" >http://dx.doi.org/10.1007/s00706-015-1469-9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-015-1469-9" target="_blank" >10.1007/s00706-015-1469-9</a>
Alternative languages
Result language
angličtina
Original language name
Determination of bromhexine at a glassy carbon paste electrode using differential pulse voltammetry and flow injection analysis with amperometric detection
Original language description
New electrochemical methods for the determination of bromhexine based on differential pulse voltammetry (DPV) and flow injection analysis with amperometric detection (FIA-ED) were developed using a glassy carbon paste electrode. Optimal supporting electrolyte for DPV measurement was methanol/Britton-Robinson buffer pH 9 (80:20, v/v). In the case of FIA-ED, optimal conditions were as follows: detection potential +1.1 V, flow rate 1.0 cm(3) min(-1), injected volume 0.1 cm(3), and carrier solution methanol-ten times diluted B-R buffer of pH 9 (80:20, v/v). Detection limit was 2.0 x 10(-6) mol dm(-3) for DPV and 3.1 x 10(-7) mol dm(-3) for FIA-ED. The applicability of the newly developed methods was verified by the determination of bromhexine in pharmaceutical preparations (tablets of Bromhexin-EGIS and Bromhexin 8 BC).
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Center of novel approaches to bioanalysis and molecular diagnostics</a><br>
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Monatshefte für Chemie
ISSN
0026-9247
e-ISSN
—
Volume of the periodical
146
Issue of the periodical within the volume
8
Country of publishing house
AT - AUSTRIA
Number of pages
5
Pages from-to
1211-1215
UT code for WoS article
000358163800003
EID of the result in the Scopus database
2-s2.0-84927555965