Determination of Trans-Resveratrol Using Voltammetric and Amperometric methods at Carbon Fiber Rod Electrode and Carbon Paste Electrode
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F12%3A10129293" target="_blank" >RIV/00216208:11310/12:10129293 - isvavai.cz</a>
Result on the web
<a href="http://www.electrochemsci.org/papers/vol7/71009221.pdf" target="_blank" >http://www.electrochemsci.org/papers/vol7/71009221.pdf</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Determination of Trans-Resveratrol Using Voltammetric and Amperometric methods at Carbon Fiber Rod Electrode and Carbon Paste Electrode
Original language description
A new method for the determination of trans-resveratrol employing voltammetry (direct current voltammetry (DCV), differential pulse voltammetry (DPV), adsorptive stripping differential pulse voltammetry (AdSDPV)) and flow injection analysis (FIA) with electrochemical detection (ED) at a carbon fiber rod electrode (CFRE) was developed and compared with the voltammetric determination using carbon paste electrode (CPE) and FIA with spectrophotometric detection (SPD). Optimum conditions were found to be Britton-Robinson (BR) buffer pH 2 - methanol (1:1, v/v) for voltammetry (except for AdSDPV where BR buffer pH 10 - methanol mixture, 95:5, v/v was used), and BR buffer pH 10 - methanol (1:1, v/v) medium with the detection potential + 1.0 V or wavelength 306nm for FIA. Practical applicability of the methods was tested on the determination of trans-resveratrol in Evelor pastilles. The results were in agreement with the results obtained using CPE and spectrophotometric detection and also with
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
—
Volume of the periodical
7
Issue of the periodical within the volume
10
Country of publishing house
RS - THE REPUBLIC OF SERBIA
Number of pages
11
Pages from-to
9221-9231
UT code for WoS article
000312933600015
EID of the result in the Scopus database
—