Dual-channel capillary electrophoresis for simultaneous determination of cations and anions

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F16%3A10324087" target="_blank" >RIV/00216208:11310/16:10324087 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11120/16:43911242

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.chroma.2016.04.015" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2016.04.015</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.chroma.2016.04.015" target="_blank" >10.1016/j.chroma.2016.04.015</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Dual-channel capillary electrophoresis for simultaneous determination of cations and anions

  • Original language description

    An original electrophoresis apparatus for simultaneous rapid determination of cations and anions has been designed and tested. The separation part of the apparatus consists of two identical fused-silica capillaries, each with a length of 10.5 cm and inner diameter of 25 mu m. The injection space is formed by the crossing of four channels in a plexiglass cross-piece. The capillaries pass through two opposing channels and their injection ends are located opposite one another at a distance of approx. 0.5 mm in the centre of the crossing point. The exit ends of the capillaries are placed in vessels containing the background electrolyte in which are immersed the electrodes of a high-voltage source. Contactless conductivity detectors with semi-cylindrical electrodes are located 2 cm from the exit ends of the capillaries. The injection part of the apparatus consists of two piezoelectric micro-pumps bringing the solution through another channel in the cross-piece to the injection ends of the capillary. During the injection, the sample is brought through one of them and is injected electrokinetically for a defined time. Then the sample zone is forced out of the injection space by a stream of background electrolyte from the second micro-pump. The timing of the injection process is computer-controlled. Thus the equipment can be considered to constitute electrophoresis in one capillary with injection into its centre. The use of short capillaries and miniature micro-pumps without other mechanical components enabled the construction of the apparatus on a board with dimensions of 20 x 25 cm.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GA15-03139S" target="_blank" >GA15-03139S: New Electrophoretic Approaches in Studies of Obesity and Diabetes</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Chromatography A

  • ISSN

    0021-9673

  • e-ISSN

  • Volume of the periodical

    1446

  • Issue of the periodical within the volume

    May

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    158-163

  • UT code for WoS article

    000375506700027

  • EID of the result in the Scopus database

    2-s2.0-84963864679