Vanillylmandelic and Homovanillic acid: Electroanalysis at non-modified and polymer-modified carbon-based electrodes

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F18%3A10376694" target="_blank" >RIV/00216208:11310/18:10376694 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1016/j.jelechem.2018.03.011" target="_blank" >https://doi.org/10.1016/j.jelechem.2018.03.011</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.jelechem.2018.03.011" target="_blank" >10.1016/j.jelechem.2018.03.011</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Vanillylmandelic and Homovanillic acid: Electroanalysis at non-modified and polymer-modified carbon-based electrodes

  • Original language description

    The electrochemical behaviour of two main catecholamine metabolites serving as diagnostic tumour biomarkers, homovanillic acid (HVA) and vanillylmandelic acid (VMA), on anodically oxidized boron doped diamond (BDD) electrodes, non-modified glassy carbon electrodes (GCE), and GCE modified by polymers, namely by Nafion (Nafion/GCE) and by poly(neutral red) (PNR/GCE), was investigated. The voltammetric responses of both biomarkers are strongly dependent on pH of the aqueous buffer solution and electrode material used. BDD electrodes exhibit more positive oxidation potentials and lower current densities for oxidation of both analytes, depending also on the surface termination. Concentration dependences were measured in 0.1 mol L-1 phosphate buffer pH 3.0, as optimal supporting electrolyte for differential pulse voltammetric determination. Achieved detection limits were 0.6, 0.9, 0.8, and 1.2 mu mol L-1 for HVA and 0.4, 1.5, 2.4, and 1.1 mu mol L-1 for VMA at BDD electrodes, non-modified GCE, Nafion/GCE, and PNR/GCE, respectively. The limits of quantification for both organic compounds on all tested electrode materials are sufficiently low for their determination in urine. Verification of the possibility of simultaneous voltammetric determination of the studied biomarkers in the mixture was also carried out.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    <a href="/en/project/GA15-02815S" target="_blank" >GA15-02815S: New recognition principles and approaches to electrochemical detection of tumor markers</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Electroanalytical Chemistry

  • ISSN

    1572-6657

  • e-ISSN

  • Volume of the periodical

    821

  • Issue of the periodical within the volume

    July

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    11

  • Pages from-to

    22-32

  • UT code for WoS article

    000437818600005