All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Comparison of static and dynamic mode in the electrochemical oxidation of fesoterodine with the use of experimental design approach

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F21%3A10435832" target="_blank" >RIV/00216208:11310/21:10435832 - isvavai.cz</a>

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=8BN76j6DE3" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=8BN76j6DE3</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2021.122141" target="_blank" >10.1016/j.talanta.2021.122141</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Comparison of static and dynamic mode in the electrochemical oxidation of fesoterodine with the use of experimental design approach

  • Original language description

    Electrochemical conversion of fesoterodine to one of its oxidation products was evaluated with the application of the wall-jet flow cell. A traditional, &quot;static&quot; mode of electrolysis was compared with the &quot;dynamic&quot; mode of cell performance. For statistical assessment of the data, experiments were planned and performed with the application of design of experiments approach, namely Taguchi L18 design. After screening phase, the experimental settings were broadened or adjusted according to the results and optimization was performed. All of the samples were electrolysed with the use of chronoamperometric method in a three electrode system. The electrolysed samples were analysed using UHPLC-PDA-QDA method. The chromatographic run was performed in gradient elution with the application of C8 column. The response was expressed as % area of the main peak found with the PDA detection method whereas QDA detector was used in positive SIM mode for structural confirmation. All data obtained for both screening and optimization were treated together and linear models were adjusted. The use of large-surface glassy carbon electrode along with pH similar to 7 were found to be the most significant factors influencing electrochemical oxidation of fesoterodine in both modes. The major differences were identified in terms of voltage applied to the electrodes which yielded the highest amounts of oxidation product. Evolution of electrochemical methods may serve as complementary technique in stress degradation studies in pharmaceutical industry.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

  • Volume of the periodical

    226

  • Issue of the periodical within the volume

    May

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    8

  • Pages from-to

    122141

  • UT code for WoS article

    000656959000054

  • EID of the result in the Scopus database

    2-s2.0-85100405220