All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Evaluation of the variation in relative response factors of GC-MS analysis with the internal standard methods: Application for the alcoholic products quality control

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F22%3A10452168" target="_blank" >RIV/00216208:11310/22:10452168 - isvavai.cz</a>

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=D-z4IlNkeJ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=D-z4IlNkeJ</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2022.123518" target="_blank" >10.1016/j.talanta.2022.123518</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Evaluation of the variation in relative response factors of GC-MS analysis with the internal standard methods: Application for the alcoholic products quality control

  • Original language description

    This paper focuses on the evaluation of variation of relative response factors (RRFs) obtained by two internal standard (IS) methods that are used to control the quality of alcoholic products. A standard IS method using 1-pentanol was compared with an &quot;Ethanol as IS&quot; method. The variation of RRF values for both methods was determined using standard solutions based on 20, 40 and 96% ethanol-water matrices. For this purpose, solutions of the ten most abundant volatile compounds were analysed at four different concentrations (250, 500, 1000 and 5000 mg L(-1) absolute alcohol, AA) within these matrices. Each solution was measured four times by gas chromatography-mass spectrometry (GC-MS) in single ion monitoring (SIM) mode under repeatability conditions. Our results showed that for the 40% and 96% matrices, the ethanol and standard IS methods showed similar relative standard deviations (RSDs) variation of no more than 2% within the 250-1000 mg L(-1) AA volatile compounds concentration range. For the 20% matrix as well as for the 250-5000 mg L(-1) AA concentration range the resulting variation in calibration factors reaches 10% for both methods. As for the whole range of 20-96% alcohol by volume (ABV) and 250-5000 mg L(-1) AA volatile concentration range, the resultant RRFs for the standard IS method (8% RSD) were more stable than those for the ethanol IS method (almost 40% RSD). Nonlinearity of the signal-to-amount dependence was also assessed with respect to the injection and detection processes.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

    1873-3573

  • Volume of the periodical

    246

  • Issue of the periodical within the volume

    August

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    123518

  • UT code for WoS article

    000892633900008

  • EID of the result in the Scopus database

    2-s2.0-85129268038