All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Fluctuation of internal standard method calibration factors based on a Taguchi designed experiment while alcoholic products analysis with GC–MS

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F22%3A10452234" target="_blank" >RIV/00216208:11310/22:10452234 - isvavai.cz</a>

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=JRdk-kzUql" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=JRdk-kzUql</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s00706-022-02942-8" target="_blank" >10.1007/s00706-022-02942-8</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Fluctuation of internal standard method calibration factors based on a Taguchi designed experiment while alcoholic products analysis with GC–MS

  • Original language description

    This paper assesses the fluctuation of relative response factors (RRFs) for the quality control of alcoholic products by GC-MS, using two internal standard (IS) methods, namely, a commonly used IS method using 1-pentanol, and &quot;Ethanol as IS&quot; method. To evaluate the variation of calibration factors values the Taguchi designed experiment was used. Matrix composition, volatile compounds concentrations, injected volume of the sample, GC injector temperature and split ratio were the five selected control factors. Within the experiment each of these control factors took one from three possible values to create 27 various measuring conditions. The results of the experiment revealed, that relative standard deviations of RRFs within all 27 measuring conditions were 7.3 +/- 4.1% for the 1-pentanol method and 36.3 +/- 3.5% for the ethanol method. The possible reasons of calibration factors variation were also discussed.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Monatshefte für Chemie - Chemical Monthly

  • ISSN

    0026-9247

  • e-ISSN

    1434-4475

  • Volume of the periodical

    153

  • Issue of the periodical within the volume

    9

  • Country of publishing house

    AT - AUSTRIA

  • Number of pages

    7

  • Pages from-to

    745-751

  • UT code for WoS article

    000824493000002

  • EID of the result in the Scopus database

    2-s2.0-85134303047