All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Monitoring of absolute mirror alignment at COMPASS RICH-1 detector

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F14%3A10284898" target="_blank" >RIV/00216208:11320/14:10284898 - isvavai.cz</a>

  • Alternative codes found

    RIV/61389021:_____/14:00435037

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.nima.2014.06.066" target="_blank" >http://dx.doi.org/10.1016/j.nima.2014.06.066</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.nima.2014.06.066" target="_blank" >10.1016/j.nima.2014.06.066</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Monitoring of absolute mirror alignment at COMPASS RICH-1 detector

  • Original language description

    The gaseous COMPASS RICH-1 detector uses two spherical mirror surfaces, segmented into 116 individual mirrors, to focus the Cherenkov photons onto the detector plane. Any mirror misalignment directly affects the detector resolution. The on-line Continuous Line Alignment and Monitoring (CLAM) photogrammetry-based method has been implemented to measure the alignment of individual mirrors which can be characterized by the center of curvature. The mirror wall reflects a regular grid of relroreflecLive strips placed inside the defector vessel. Then, the position of each mirror is determined from the image of the grid reflection. The images are collected by four cameras. Any small mirror misalignment results in changes of the grid lines' positions in the image. The accuracy limits of the CLAM method were checked by laser inlerferomary and are below 0.1 mrad. (C) 2014 Elsevier B.V. All rights reserved.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    BF - Elementary particle theory and high energy physics

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/LG13031" target="_blank" >LG13031: Collaboration of the Czech Republic with CERN</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

  • ISSN

    0168-9002

  • e-ISSN

  • Volume of the periodical

    766

  • Issue of the periodical within the volume

    December

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    4

  • Pages from-to

    208-211

  • UT code for WoS article

    000344622200049

  • EID of the result in the Scopus database