Monitoring of absolute mirror alignment at COMPASS RICH-1 detector
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F14%3A10284898" target="_blank" >RIV/00216208:11320/14:10284898 - isvavai.cz</a>
Alternative codes found
RIV/61389021:_____/14:00435037
Result on the web
<a href="http://dx.doi.org/10.1016/j.nima.2014.06.066" target="_blank" >http://dx.doi.org/10.1016/j.nima.2014.06.066</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2014.06.066" target="_blank" >10.1016/j.nima.2014.06.066</a>
Alternative languages
Result language
angličtina
Original language name
Monitoring of absolute mirror alignment at COMPASS RICH-1 detector
Original language description
The gaseous COMPASS RICH-1 detector uses two spherical mirror surfaces, segmented into 116 individual mirrors, to focus the Cherenkov photons onto the detector plane. Any mirror misalignment directly affects the detector resolution. The on-line Continuous Line Alignment and Monitoring (CLAM) photogrammetry-based method has been implemented to measure the alignment of individual mirrors which can be characterized by the center of curvature. The mirror wall reflects a regular grid of relroreflecLive strips placed inside the defector vessel. Then, the position of each mirror is determined from the image of the grid reflection. The images are collected by four cameras. Any small mirror misalignment results in changes of the grid lines' positions in the image. The accuracy limits of the CLAM method were checked by laser inlerferomary and are below 0.1 mrad. (C) 2014 Elsevier B.V. All rights reserved.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BF - Elementary particle theory and high energy physics
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/LG13031" target="_blank" >LG13031: Collaboration of the Czech Republic with CERN</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Volume of the periodical
766
Issue of the periodical within the volume
December
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
4
Pages from-to
208-211
UT code for WoS article
000344622200049