All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Strong negative interference of ethamsylate (Dicynone (R)) in serum creatinine quantification via enzymatic assay using Trinder reaction

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F13%3A00069727" target="_blank" >RIV/00216224:14110/13:00069727 - isvavai.cz</a>

  • Alternative codes found

    RIV/65269705:_____/13:#0002079

  • Result on the web

    <a href="http://dx.doi.org/10.3109/00365513.2013.794300" target="_blank" >http://dx.doi.org/10.3109/00365513.2013.794300</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3109/00365513.2013.794300" target="_blank" >10.3109/00365513.2013.794300</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Strong negative interference of ethamsylate (Dicynone (R)) in serum creatinine quantification via enzymatic assay using Trinder reaction

  • Original language description

    Background. With discrepancies encountered as early as the verification of enzymatic method for quantification of serum creatinine, our research pointed to a later confirmed interference caused by a compound called ethamsylate present in the commonly used antihemorrhagic drug Dicynone. Methods. We measured concentrations of creatinine of 10 patients with blood taken before and 15 minutes after the intravenous administration of a 500 mg dose of Dicynone. The creatinine concentration was determined usingJaffe method and enzymatic method that utilize Trinder reaction (Roche) in analyzer Cobas c 501 (Roche AG, Basel, Switzerland). We also monitored concentration of blood creatinine in three patients before and 15 minutes after application of Dicynone (500mg i.v.) and in the following 6th, 12th, 18th, and 24th hours. Results. We discovered a significant negative bias in creatinine results using enzymatic assay with Trinder reaction in blood taken 15 min after i.v.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CE - Biochemistry

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION

  • ISSN

    0036-5513

  • e-ISSN

  • Volume of the periodical

    73

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    3

  • Pages from-to

    449-451

  • UT code for WoS article

    000323106700014

  • EID of the result in the Scopus database