All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Pupillary Response to Chromatic Stimuli

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F14%3A00078374" target="_blank" >RIV/00216224:14110/14:00078374 - isvavai.cz</a>

  • Alternative codes found

    RIV/00159816:_____/14:00061444

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    čeština

  • Original language name

    Pupilární reakce na barevné podněty

  • Original language description

    Aim of study: To compare chromatic pupillary responses in a group of healthy subjects and to determine if this method can be used for assessing outer and inner retinal function. Material and methods: The study group consisted of 17 healthy subjects. Subjects were tested with a chromatic pupillometer. The parameters of the stimulus were as follows: intensity 28 lx, duration 4 sec, and color blue (420 +/- 20 nm) and red (605 +/- 20 nm). The examined pupil parameters were baseline pupil diameter, maximal constriction time, relative amplitude at maximal constriction, at 3 sec after stimulus onset, at stimulus offset, at 3 sec after stimulus offset and at 7 sec after stimulus offset. Pupil response parameters to red and blue light were evaluated by paired t-test. Results: Except for the baseline pupil diameter (p = 0.148), there was a significant difference in all pupil response parameters to red and blue light (p = 0.001).

  • Czech name

    Pupilární reakce na barevné podněty

  • Czech description

    Aim of study: To compare chromatic pupillary responses in a group of healthy subjects and to determine if this method can be used for assessing outer and inner retinal function. Material and methods: The study group consisted of 17 healthy subjects. Subjects were tested with a chromatic pupillometer. The parameters of the stimulus were as follows: intensity 28 lx, duration 4 sec, and color blue (420 +/- 20 nm) and red (605 +/- 20 nm). The examined pupil parameters were baseline pupil diameter, maximal constriction time, relative amplitude at maximal constriction, at 3 sec after stimulus onset, at stimulus offset, at 3 sec after stimulus offset and at 7 sec after stimulus offset. Pupil response parameters to red and blue light were evaluated by paired t-test. Results: Except for the baseline pupil diameter (p = 0.148), there was a significant difference in all pupil response parameters to red and blue light (p = 0.001).

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FF - ENT (ie. ear, nose, throat), ophthalmology, dentistry

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Česká a Slovenská neurologie a neurochirurgie

  • ISSN

    1210-7859

  • e-ISSN

  • Volume of the periodical

    77

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    5

  • Pages from-to

    334-338

  • UT code for WoS article

    000336563200010

  • EID of the result in the Scopus database