Automatic Evaluation of Collagen Fiber Directions from Polarized Light Microscopy Images

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00084554" target="_blank" >RIV/00216224:14110/15:00084554 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216305:26210/15:PU114247

  • Result on the web

    <a href="http://dx.doi.org/10.1017/S1431927615000586" target="_blank" >http://dx.doi.org/10.1017/S1431927615000586</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1017/S1431927615000586" target="_blank" >10.1017/S1431927615000586</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Automatic Evaluation of Collagen Fiber Directions from Polarized Light Microscopy Images

  • Original language description

    Mechanical properties of the arterial wall depend largely on orientation and density of collagen fiber bundles. Several methods have been developed for observation of collagen orientation and density; the most frequently applied collagen-specific manualapproach is based on polarized light (PL). However, it is very time consuming and the results are operator dependent. We have proposed a new automated method for evaluation of collagen fiber direction from two-dimensional polarized light microscopy images (2D PLM). The algorithm has been verified against artificial images and validated against manual measurements. Finally the collagen content has been estimated. The proposed algorithm was capable of estimating orientation of some 35 k points in 15 min when applied to aortic tissue and over 500 k points in 35 min for Achilles tendon. The average angular disagreement between each operator and the algorithm was -9.3 +/- 8.6 degrees and -3.8 +/- 8.6 degrees in the case of aortic tissue and

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FP - Other medical fields

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Microscopy and Microanalysis

  • ISSN

    1431-9276

  • e-ISSN

  • Volume of the periodical

    21

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    13

  • Pages from-to

    863-875

  • UT code for WoS article

    000358834600008

  • EID of the result in the Scopus database