Association between ventricular pacing and persistent atrial fibrillation in patients indicated to elective pacemaker replacement: Results of the Prefer for Elective Replacement MVP (PreFER MVP) randomized study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00086546" target="_blank" >RIV/00216224:14110/15:00086546 - isvavai.cz</a>
Alternative codes found
RIV/65269705:_____/15:00063970
Result on the web
<a href="http://dx.doi.org/10.1016/j.hrthm.2015.06.041" target="_blank" >http://dx.doi.org/10.1016/j.hrthm.2015.06.041</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.hrthm.2015.06.041" target="_blank" >10.1016/j.hrthm.2015.06.041</a>
Alternative languages
Result language
angličtina
Original language name
Association between ventricular pacing and persistent atrial fibrillation in patients indicated to elective pacemaker replacement: Results of the Prefer for Elective Replacement MVP (PreFER MVP) randomized study
Original language description
BACKGROUND Pacing in the right ventricle can cause a variety of detrimental effects, including atrial tachyarrhythmias (atrial tachycardia [AT]/atrial fibrillation [AF]). OBJECTIVE The purpose of this study was to evaluate the incidence and predictors ofpersistent AT/AF in patients with long-term exposure to ventricular pacing. METHODS In a multicenter international trial, 605 patients (age 75 +/- 11 years, 240 women) referred for replacement of an implanted pacemaker or implantable cardioverter-defibrillator (ICD), with a history of high-percentage (>40%) ventricular pacing, were randomly allocated to standard dual-chamber pacing or managed ventricular pacing (MVP), a pacing modality that minimizes ventricular pacing. The main end-point of this secondary analysis of the PreFER MVP randomized study was persistent AT/AF, defined as >= 7 consecutive days with AT/AF or AT/AF interrupted by atrial cardioversion or AT/AF present during 2 consecutive follow-up visits.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Heart Rhythm
ISSN
1547-5271
e-ISSN
—
Volume of the periodical
12
Issue of the periodical within the volume
11
Country of publishing house
US - UNITED STATES
Number of pages
8
Pages from-to
2239-2246
UT code for WoS article
000366112600009
EID of the result in the Scopus database
—