All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Endoluminal radiofrequency ablation of malignant biliary stenoses

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00087460" target="_blank" >RIV/00216224:14110/15:00087460 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1007/s13244-015-0387-z" target="_blank" >http://dx.doi.org/10.1007/s13244-015-0387-z</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s13244-015-0387-z" target="_blank" >10.1007/s13244-015-0387-z</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Endoluminal radiofrequency ablation of malignant biliary stenoses

  • Original language description

    Purpose: To prove efficacy of endoluminal radiofrequency ablation before stenting of malignant biliary stenoses. Methods and Materials: 54 patients with histologically proven malignant biliary stenoses have been enrolled in a prospective randomised study from 2010. 73 non-covered self-expandable metal stents were inserted. In group A (n=22) the endoluminal ablation with a bipolar radiofrequency catheter (EndoHPB;EMcision Ltd.,London,UK) was performed 0-48hours prior to the stent insertion, in group B (n=32) the stent was implanted without a prior ablation. The primary endpoints of the study were to determine the rate of complications, duration of stent patency and survival of patients (Kaplan-Meyer analysis). Results: No major complications related to the stent insertion and endoluminal ablation were recorded. 30 day mortality was 3.7%. The average primary stent patency was 5.6 and 5.2 months in group A and B, respectively, 3-months and 6-months stent failure was 9.1% and 13.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

    FP - Other medical fields

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/NT14586" target="_blank" >NT14586: Radiofrequency ablation of bile ducts under choledochoscopy guidance</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů