Biocompatibility of NiTi alloys in the cell behaviour
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F17%3A00094656" target="_blank" >RIV/00216224:14110/17:00094656 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1007/s10534-017-0002-5" target="_blank" >http://dx.doi.org/10.1007/s10534-017-0002-5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10534-017-0002-5" target="_blank" >10.1007/s10534-017-0002-5</a>
Alternative languages
Result language
angličtina
Original language name
Biocompatibility of NiTi alloys in the cell behaviour
Original language description
Metallic biomaterial alloys composed of nickel and titanium have unique thermal shape memory, superelastic, and high damping properties, which are widely used in the medicine. The major parameter evaluated in the studies regarding the behaviour of the material in the contact with organism or cells is biocompatibility. The aim of the studies is to clarify the differences in the proliferation, growth, and morphology especially in the cell cultures. The cytotoxicity is affected among other by release of the metal ions in the presence of the metal alloy, which is further dependent on the possible treatments of the material and the corrosive properties. To evaluate the cytotoxicity, wide range of tests including the Sulforhodamine B assay and MTT tests, expression profiles, cell survival tests such as apoptotic test are used. The review compares the cell behaviour in contact with the material alloys composed of nickel and titanium with respect to different materials composition and different surface treatment that affects the ion release. Even though the results published so far are controversial, almost all data suggest sufficient biocompatibility in medical use.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10608 - Biochemistry and molecular biology
Result continuities
Project
<a href="/en/project/GA15-16336S" target="_blank" >GA15-16336S: Interstitial impurities in NiTi-based shape memory alloys</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
BioMetals
ISSN
0966-0844
e-ISSN
—
Volume of the periodical
30
Issue of the periodical within the volume
2
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
7
Pages from-to
163-169
UT code for WoS article
000398709100002
EID of the result in the Scopus database
—