Simulation of the biliary metal stent recanalisation using endoluminal irreversible electroporation on porcine liver - in vivo experiment
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F19%3A00110835" target="_blank" >RIV/00216224:14110/19:00110835 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1007/s00270-019-02282-x" target="_blank" >http://dx.doi.org/10.1007/s00270-019-02282-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00270-019-02282-x" target="_blank" >10.1007/s00270-019-02282-x</a>
Alternative languages
Result language
angličtina
Original language name
Simulation of the biliary metal stent recanalisation using endoluminal irreversible electroporation on porcine liver - in vivo experiment
Original language description
Purpose: To demonstrate feasibility of endoluminal irreversible electroporation using tubular catheter in biliary metal stent for recanalisation. Material and methods: 25 simulations of metal stent obstruction on porcine liver in vivo were performed by liver lower edge incision and its insertion in the biliary metal stent. In 14 cases endoluminal irreversible electroporation with tubular catheter prototype were performed, others were set as controls. Three diferent scenarios of IRE were simulated (one, two or zero electrodes in contact with metal stent). Ninety 100 us pulses with 300,650,1000 and 1300 Volts were used in each scenario. Electrical parameters, macroscopical changes, side efects were monitored during the procedure. Early complications were evaluated by CT immediately and 72 hours after the procedure, followed by samples harvesting. Results: There were no complications detected during the procedure and on following CTs, enduluminal IRE was succesful in all cases. Signifcant diference in impedance was observed between all scenario settings (p=0,02, Mann-Whitey). Short circuit occured immediately in 1300 V in all scenarios, in both cases of 1000 V with one electrode in contact with stent and in case where both electrodes were in contact with stent. The highest observed safe voltage for IRE in metal stent was 850 V/cm. Histopathological analysis showed signs of tissue necrosis which were not present in control samples. Conclusion: Endoluminal irreversible electroporation using tubular catheter seems safe and feasible method and has potential for non-thermal metal stent ingrowth treatment.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů