Heart Rate Dependency and Inter-Lead Variability of the T Peak - T End Intervals
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F20%3A00117726" target="_blank" >RIV/00216224:14110/20:00117726 - isvavai.cz</a>
Alternative codes found
RIV/65269705:_____/20:00073363
Result on the web
<a href="https://www.frontiersin.org/articles/10.3389/fphys.2020.595815/full" target="_blank" >https://www.frontiersin.org/articles/10.3389/fphys.2020.595815/full</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fphys.2020.595815" target="_blank" >10.3389/fphys.2020.595815</a>
Alternative languages
Result language
angličtina
Original language name
Heart Rate Dependency and Inter-Lead Variability of the T Peak - T End Intervals
Original language description
The electrocardiographic (ECG) assessment of the T peak-T end (Tpe) intervals has been used in many clinical studies, but several related physiological aspects have not been reported. Specifically, the sources of the Tpe differences between different ECG leads have not been systematically researched, the relationship of Tpe duration to underlying heart rate has not been firmly established, and little is known about the mutual correspondence of Tpe intervals measured in different ECG leads. This study evaluated 796,620 10-s 12-lead ECGs obtained from long-term Holters recorded in 639 healthy subjects (311 female) aged 33.8 +/- 9.4 years. For each ECG, transformation to orthogonal XYZ lead was used to measure Tpe in the orthogonal vector magnitude (used as a reference for lead-to-lead comparisons) and to construct a three-dimensional T wave loop. The loop roundness was expressed by a ratio between its circumference and length. These ratios were significantly related to the standard deviation of Tpe durations in different ECG leads. At the underlying heart rate of 60 beats per minute, Tpe intervals were shorter in female than in male individuals (82.5 +/- 5.6 vs 90.0 +/- 6.5 ms, p < 0.0001). When studying linear slopes between Tpe intervals measured in different leads and the underlying heart rate, we found only minimal heart rate dependency, which was not systematic across the ECG leads and/or across the population. For any ECG lead, positive Tpe/RR slope was found in some subjects (e.g., 79 and 25% of subjects for V2 and V4 measurements, respectively) and a negative Tpe/RR slope in other subjects (e.g., 40 and 65% for V6 and V5, respectively). The steepest positive and negative Tpe/RR slopes were found for measurements in lead V2 and V4, respectively. In all leads, the Tpe/RR slope values were close to zero, indicating, on average, Tpe changes well below 2 ms for RR interval changes of 100 ms. On average, longest Tpe intervals were measured in lead V2, the shortest in lead III. The study concludes that the Tpe intervals measured in different leads cannot be combined. Irrespective of the measured ECG lead, the Tpe interval is not systematically heart rate dependent, and no heart rate correction should be used in clinical Tpe investigations.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30105 - Physiology (including cytology)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Frontiers in Physiology
ISSN
1664-042X
e-ISSN
—
Volume of the periodical
11
Issue of the periodical within the volume
DEC 2020
Country of publishing house
CH - SWITZERLAND
Number of pages
19
Pages from-to
1-19
UT code for WoS article
000603040500001
EID of the result in the Scopus database
2-s2.0-85098530219