Silver(I) Ions Ultrasensitive Detection at Carbon Electrodes-Analysis of Waters, Tobacco Cells and Fish Tissues
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F09%3A00037454" target="_blank" >RIV/00216224:14310/09:00037454 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26220/09:PU85146 RIV/70883521:28610/09:63508770 RIV/62157124:16270/09:00002131 RIV/62156489:43210/09:00152389
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Silver(I) Ions Ultrasensitive Detection at Carbon Electrodes-Analysis of Waters, Tobacco Cells and Fish Tissues
Original language description
We used carbon paste electrodes and a standard potentiostat to detect silver ions. The detection limit (3 Signal/Noise ratio) was estimated as 0.5 mu M. A standard electrochemical instrument microanalysis of silver(I) ions was suggested. As a working electrode a carbon tip (1 mL) or carbon pencil was used. Limits of detection estimated by dilution of a standard were 1 (carbon tip) or 10 nM (carbon pencil). Further we employed flow injection analysis coupled with carbon tip to detect silver(I) ions released in variousbeverages and mineral waters. During first, second and third week the amount of silver(I) ions releasing into water samples was under the detection limit of the technique used for their quantification. At the end of a thirteen weeks long experiment the content of silver(I) ions was several times higher compared to the beginning of release detected in the third week and was on the order of tens of nanomoles.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/KAN208130801" target="_blank" >KAN208130801: New design and exploiting nanobiosensors and nanosensors to target medicine (NANOSEMED)</a><br>
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2009
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Sensors
ISSN
1424-8220
e-ISSN
—
Volume of the periodical
9
Issue of the periodical within the volume
9
Country of publishing house
CH - SWITZERLAND
Number of pages
2
Pages from-to
—
UT code for WoS article
—
EID of the result in the Scopus database
—