Evaluation of sample preparation protocols for spider venom profiling by MALDI-TOF MS
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F17%3A00094825" target="_blank" >RIV/00216224:14310/17:00094825 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.toxicon.2017.04.008" target="_blank" >http://dx.doi.org/10.1016/j.toxicon.2017.04.008</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.toxicon.2017.04.008" target="_blank" >10.1016/j.toxicon.2017.04.008</a>
Alternative languages
Result language
angličtina
Original language name
Evaluation of sample preparation protocols for spider venom profiling by MALDI-TOF MS
Original language description
Spider venoms are highly complex mixtures containing biologically active substances with potential for use in biotechnology or pharmacology. Fingerprinting of venoms by Matrix-Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS) is a thriving technology, enabling the rapid detection of peptide/protein components that can provide comparative information. In this study, we evaluated the effects of sample preparation procedures on MALDI-TOF mass spectral quality to establish a protocol providing the most reliable analytical outputs. We adopted initial sample preparation conditions from studies already published in this field. Three different MALDI matrixes, three matrix solvents, two sample deposition methods, and different acid concentrations were tested. As a model sample, venom from Brachypelma albopilosa was used. The mass spectra were evaluated on the basis of absolute and relative signal intensities, and signal resolution. By conducting three series of analyses at three weekly intervals, the reproducibility of the mass spectra were assessed as a crucial factor in the selection for optimum conditions. A sample preparation protocol based on the use of an HCCA matrix dissolved in 50% acetonitrile with 2.5% TFA deposited onto the target by the dried-droplet method was found to provide the best results in terms of information yield and repeatability. We propose that this protocol should be followed as a standard procedure, enabling the comparative assessment of MALDI-TOF MS spider venom fingerprints.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Toxicon
ISSN
0041-0101
e-ISSN
—
Volume of the periodical
133
Issue of the periodical within the volume
July
Country of publishing house
GB - UNITED KINGDOM
Number of pages
8
Pages from-to
18-25
UT code for WoS article
000403864000003
EID of the result in the Scopus database
—