Symmetry of the Fornix Using Diffusion Tensor Imaging
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F14%3A00075878" target="_blank" >RIV/00216224:14740/14:00075878 - isvavai.cz</a>
Result on the web
<a href="http://onlinelibrary.wiley.com/doi/10.1002/jmri.24424/pdf" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/jmri.24424/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jmri.24424" target="_blank" >10.1002/jmri.24424</a>
Alternative languages
Result language
angličtina
Original language name
Symmetry of the Fornix Using Diffusion Tensor Imaging
Original language description
Purpose: To: 1) Present fornix tractography in its entirety for 20 healthy individuals to assess variability. 2) Provide individual and groupwise whole tract diffusion parameter symmetry assessments prior to clinical application. 3) Compare whole tract diffusion parameter assessments with tract-based spatial statistics (TBSS). Materials and Methods: Diffusion tensor imaging (DTI) data were acquired on a 3T Siemens magnetic resonance imaging (MRI) system using a single-shot spin echo planar imaging (EPI)sequence. Individual fornix tractography was conducted and whole tract diffusion parameter symmetries assessed. Whole tract results were compared with asymmetry contrasts conducted with voxelwise statistical analysis of diffusion parameters using TBSS.Results: The fornix tract could be visualized in its entirety including the columns, body, crura, and fimbria. Contrary to the crus and body, there were some tractography inconsistencies of the columns and fimbria across subjects.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FH - Neurology, neuro-surgery, nuero-sciences
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Magnetic Resonance Imaging
ISSN
1053-1807
e-ISSN
—
Volume of the periodical
40
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
8
Pages from-to
929-936
UT code for WoS article
000342342500022
EID of the result in the Scopus database
—