All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Cyclopropylamine plasma polymer surfaces for label-free SPR and QCM immunosensing of Salmonella

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F18%3A00101169" target="_blank" >RIV/00216224:14740/18:00101169 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.snb.2018.08.055" target="_blank" >http://dx.doi.org/10.1016/j.snb.2018.08.055</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.snb.2018.08.055" target="_blank" >10.1016/j.snb.2018.08.055</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Cyclopropylamine plasma polymer surfaces for label-free SPR and QCM immunosensing of Salmonella

  • Original language description

    We report on the first successful application of nitrogen-containing functional surfaces prepared by plasma polymerization in surface plasmon resonance (SPR) immunosensing. The plasma polymers (PPs) were deposited from cyclopropylamine (CPA) vapors onto gold surfaces of SPR and quartz crystal microbalance (QCM) sensors. It provided an excellent platform for a stable immobilization of antibodies using glutaraldehyde (GA) activation. The performance of the SPR immunosensor was proven by a model pair of monoclonal antibody (Ab) AL-01 and human serum albumin as well as by the selective detection of bacterial pathogen Salmonella Typhimurium using the immobilized anti-Salmonella Ab. A baseline drift of the measured SPR signal, caused by the long-term reactivity of CPA plasma polymers, was well stabilized by 18 h immersion in phosphate buffered saline prior to the GA activation. The immunosensors can be successfully regenerated several times using 10 mM NaOH. The limit of detection of 10^5 CFU/mL and a wide linear response were achieved for Salmonella. The assay parameters are comparable to the conventional label-free methods. However, the replacement of conventional immobilization matrix with the CPA PPs offers an advantage of excellent adhesion to gold QCM and SPR surfaces achieved by fast and eco-friendly procedure compatible with the vacuum deposition of gold.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Sensors and Actuators B: Chemical

  • ISSN

    0925-4005

  • e-ISSN

  • Volume of the periodical

    276

  • Issue of the periodical within the volume

    DEC

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    9

  • Pages from-to

    447-455

  • UT code for WoS article

    000444637600056

  • EID of the result in the Scopus database

    2-s2.0-85052620714