Silver Composite Electrode for Voltammetric Determination of Halogenides
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F04%3A00001586" target="_blank" >RIV/00216275:25310/04:00001586 - isvavai.cz</a>
Alternative codes found
RIV/61388955:_____/04:00101056 RIV/00216208:11110/04:00007957
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Silver Composite Electrode for Voltammetric Determination of Halogenides
Original language description
The application of the silver composite electrode prepared from silver, graphite powder and methacrylate resin for the voltammetric determination of halogenide ions was studied. Cathodic direct current (DC) as well as differential pulse (DP) stripping voltammetry (DPV) enable direct determination of chloride, bromide, as well as iodide ions. The achieved limits of detection for all determined ions are sufficient for practical analytical purposes (tap water, natural water, etc.) and results reported in this paper are fully comparable with results achieved using other electrodes. The possibilities of sample analysis without elimination of the presence of surface-active substances or of dissolved oxygen were studied. The silver composite electrode represents a suitable sensor for analytical purposes and seems to be promising for replacement of electrodes in many cases.
Czech name
Stříbrná kompozitní elektroda pro voltametrické stanovení halogenidů
Czech description
Stříbrná kompozitní elektroda pro voltametrické stanovení halogenidů
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GA101%2F02%2F0011" target="_blank" >GA101/02/0011: New approach to the analysis of dynamic behaviour of nonlinear coupling elements using in rotor dynamic systems</a><br>
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2004
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Analytical Letters
ISSN
ISSN 0003-271
e-ISSN
—
Volume of the periodical
37
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
26
Pages from-to
603-628
UT code for WoS article
—
EID of the result in the Scopus database
—