Combined Macro-/Mesoporous Microelectrode Arrays for Low-Noise Extracellular Recording of Neural Networks
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F12%3A39895329" target="_blank" >RIV/00216275:25310/12:39895329 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1152/jn.00711.2011" target="_blank" >http://dx.doi.org/10.1152/jn.00711.2011</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1152/jn.00711.2011" target="_blank" >10.1152/jn.00711.2011</a>
Alternative languages
Result language
angličtina
Original language name
Combined Macro-/Mesoporous Microelectrode Arrays for Low-Noise Extracellular Recording of Neural Networks
Original language description
Microelectrode arrays (MEAs) are appealing tools to probe large neural ensembles and build neural prostheses. Microelectronics microfabrication technologies now allow building high-density MEAs containing several hundreds of microelectrodes. However, several major problems become limiting factors when the size of the microelectrodes decreases. In particular, regarding recording of neural activity, the intrinsic noise level of a microelectrode dramatically increases when the size becomes small (typicallybelow 20-mu m diameter). Here, we propose to overcome this limitation using a template-based, single-scale meso-or two-scale macro-/mesoporous modification of the microelectrodes, combining the advantages of an overall small geometric surface and an active surface increased by several orders of magnitude. For this purpose, standard platinum MEAs were covered with a highly porous platinum overlayer obtained by lyotropic liquid crystal templating possibly in combination with a microsphere
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/LC06035" target="_blank" >LC06035: Centre of Biophysical Chemistry, Bioelectrochemistry and Bioanalysis. New Tools for Genomics, Proteomics and Biomedicine.</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
JOURNAL OF NEUROPHYSIOLOGY
ISSN
0022-3077
e-ISSN
—
Volume of the periodical
108
Issue of the periodical within the volume
6
Country of publishing house
US - UNITED STATES
Number of pages
11
Pages from-to
1793-1803
UT code for WoS article
000309000100021
EID of the result in the Scopus database
—