Effects of fatty acyl chain length, double-bond number and matrix on phosphatidylcholine responses in matrix-assisted laser desorption/ionization on an Orbitrap mass spectrometer
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F15%3A39899701" target="_blank" >RIV/00216275:25310/15:39899701 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1002/rcm.7404" target="_blank" >http://dx.doi.org/10.1002/rcm.7404</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/rcm.7404" target="_blank" >10.1002/rcm.7404</a>
Alternative languages
Result language
angličtina
Original language name
Effects of fatty acyl chain length, double-bond number and matrix on phosphatidylcholine responses in matrix-assisted laser desorption/ionization on an Orbitrap mass spectrometer
Original language description
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is used for the fast qualitative and quantitative analysis of phosphatidylcholines (PC). Fatty acyl chain lengths and the number of double bonds (DB) affect relative responses of PC; hence the determination of correction factors of individual PC is important for the accurate quantitation. The signal intensity in MALDI-MS strongly depends on the matrix; therefore, the following matrices typically used in lipidomics are studied in the present work: 2,5-dihydroxybenzoic acid (DHB), 1,5- diaminonaphthalene (DAN) and 9-aminoacridine (9AA).
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Rapid Communication in Mass Spectrometry
ISSN
0951-4198
e-ISSN
—
Volume of the periodical
29
Issue of the periodical within the volume
24
Country of publishing house
GB - UNITED KINGDOM
Number of pages
11
Pages from-to
2374-2384
UT code for WoS article
000364876400007
EID of the result in the Scopus database
—