An integrated microfluidic chip for immunocapture, preconcentration and separation of ?-amyloid peptides
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F15%3A39900560" target="_blank" >RIV/00216275:25310/15:39900560 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1063/1.4931394" target="_blank" >http://dx.doi.org/10.1063/1.4931394</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4931394" target="_blank" >10.1063/1.4931394</a>
Alternative languages
Result language
angličtina
Original language name
An integrated microfluidic chip for immunocapture, preconcentration and separation of ?-amyloid peptides
Original language description
We present an integrated microfluidic chip for detection of ?-amyloid (A?) peptides. A? peptides are major biomarkers for the diagnosis of Alzheimer's disease (AD) in its early stages. This microfluidic device consists of three main parts: (1) An immunocapture microcolumn based on self-assembled magnetic beads coated with antibodies specific to A? peptides, (2) a nano-porous membrane made of photopolymerized hydrogel for preconcentration, and (3) a microchip electrophoresis (MCE) channel with fluorescent detection. Sub-milliliter sample volume is either mixed off-chip with antibody coated magnetic beads and injected into the device or is injected into an already self-assembled column of magnetic beads in the microchannel. The captured peptides on the beads are then electrokinetically eluted and re-concentrated onto the nano-membrane in a few nano-liters. By integrating the nano-membrane, total assay time was reduced and also off-chip re-concentration or buffer exchange steps were not n
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/7E12083" target="_blank" >7E12083: NAnosystems for the early DIagnosis of NEurodegenerative Diseases</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biomicrofluidics
ISSN
1932-1058
e-ISSN
—
Volume of the periodical
9
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
8
Pages from-to
054117
UT code for WoS article
000364407300029
EID of the result in the Scopus database
—