All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Investigation of the temperature dependence of water adsorption from aqueous acetonitrile on silica-based stationary phases in hydrophilic interaction liquid chromatography

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39911197" target="_blank" >RIV/00216275:25310/17:39911197 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.chroma.2017.02.011" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2017.02.011</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.chroma.2017.02.011" target="_blank" >10.1016/j.chroma.2017.02.011</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Investigation of the temperature dependence of water adsorption from aqueous acetonitrile on silica-based stationary phases in hydrophilic interaction liquid chromatography

  • Original language description

    In the present work, the adsorption of water was investigated in aqueous normal-phase liquid chromatography on Cogent Silica C and Cogent Phenyl hydride stationary phases at different temperatures by frontal analysis – using coulometric Karl Fischer titration – to compare the temperature dependence of adsorption of water from aqueous acetonitrile. The Cogent Silica-C and Cogent Phenyl Hydride columns have a silicon hydride surface (silica hydride) with less than 2% free silanol group; therefore, they do not have a strong association with water. The adsorption behavior of water on the mentioned stationary phases was modeled by Langmuir isotherm. The preferentially adsorbed water was expressed in terms of a hypothetical monomolecular water layer equivalent in the inner pores. The uptake of water slightly depends on the temperature. The adsorbed water may fill four to eight percent of the pore volume over the studied temperature range, which approximately corresponds to the equivalent of 0.24–0.68 water layer coverage of the adsorbent surface. The phenyl hydride stationary phase shows decreased water uptake in comparison to the Silica C stationary phase.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Chromatography A

  • ISSN

    0021-9673

  • e-ISSN

  • Volume of the periodical

    1489

  • Issue of the periodical within the volume

    March

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    143-148

  • UT code for WoS article

    000397359900016

  • EID of the result in the Scopus database