Ultrahigh-performance supercritical fluid chromatography - mass spectrometry for the qualitative analysis of metabolites covering a large polarity range
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F22%3A39918845" target="_blank" >RIV/00216275:25310/22:39918845 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0021967322000309" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0021967322000309</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2022.462832" target="_blank" >10.1016/j.chroma.2022.462832</a>
Alternative languages
Result language
angličtina
Original language name
Ultrahigh-performance supercritical fluid chromatography - mass spectrometry for the qualitative analysis of metabolites covering a large polarity range
Original language description
The applicability of ultrahigh-performance supercritical fluid chromatography coupled with mass spectrometry (UHPSFC/MS) for the qualitative analysis of metabolites with a wide polarity range (log P: -3.89-18.95) was evaluated using a representative set of 78 standards belonging to nucleosides, biogenic amines, carbohydrates, amino acids, and lipids. The effects of the gradient shape and the percentage of water (1, 2, and 5%) were investigated on the Viridis BEH column. The screening of eight stationary phases was performed for columns with different interaction sites, such as hydrogen bonding, hydrophobic, pi-pi, or anionic exchange type interactions. The highest number of compounds (67) of the set studied was detected on the Torus Diol column, which provided a resolution parameter of 39. The DEA column had the second best performance with 58 detected standards and the resolution parameter of 54. The overall performance of other parameters, such as selectivity, peak height, peak area, retention time stability, asymmetry factor, and mass accuracy, led to the selection of the Diol column for the final method. The comparison of additives showed that ammonium acetate gave a superior sensitivity over ammonium formate. Moreover, the influence of the ion source on the ionization efficiency was studied by employing atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The results proved the complementarity of both ionization techniques, but also the superior ionization capacity of the ESI source in the negative ion mode, for which 53% of the analytes were detected compared to only 7% for the APCI source. Finally, optimized analytical conditions were applied to the analysis of a pooled human plasma sample. 44 compounds from the preselected set were detected in human plasma using ESI-UHPSFC/MS in MS E mode considering both ionization modes. (C) 2022 Published by Elsevier B.V.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
<a href="/en/project/GJ20-23290Y" target="_blank" >GJ20-23290Y: Supercritical fluid chromatography hyphenated to mass spectrometry for the absolute quantitation of ionic and polar biomolecules</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
1873-3778
Volume of the periodical
1665
Issue of the periodical within the volume
February
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
12
Pages from-to
462832
UT code for WoS article
000766209700005
EID of the result in the Scopus database
2-s2.0-85123050001