Comparison between Dynamic and Static Metrics for Daylight Evaluation in the Case of Obstructed Buildings
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F16%3APU121876" target="_blank" >RIV/00216305:26110/16:PU121876 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.861.477" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMM.861.477</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.861.477" target="_blank" >10.4028/www.scientific.net/AMM.861.477</a>
Alternative languages
Result language
angličtina
Original language name
Comparison between Dynamic and Static Metrics for Daylight Evaluation in the Case of Obstructed Buildings
Original language description
Daylight in buildings can be evaluated using dynamic and static daylight metrics. The daylight factor is a static daylight metric which evaluates daylight conditions under the overcast sky model according to the International Commission on Illumination. However, the dynamic daylight metrics (e.g. daylight autonomy, spatial daylight autonomy, useful daylight illuminance) can be more complex evaluation criteria because they are based on annual daylight illuminance data for a building site. While the daylight factor value depends only on a room geometry, optical properties of surfaces and positioning of daylight obstructions, the dynamic daylight metrics also include an effect of a building location, window orientation or building occupancy pattern. The article deals with a comparison of a daylight evaluation using dynamic and static daylight metrics in the case of buildings whose daylight is obstructed by external barriers.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20101 - Civil engineering
Result continuities
Project
<a href="/en/project/LO1408" target="_blank" >LO1408: AdMaS UP – Advanced Building Materials, Structures and Technologies</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Buildings and Environment - Energy Performance, Smart Materials and Buildings
ISBN
978-3-0357-1070-0
ISSN
1660-9336
e-ISSN
—
Number of pages
8
Pages from-to
477-484
Publisher name
Trans Tech Publications
Place of publication
Switzerland
Event location
Brno
Event date
Sep 22, 2016
Type of event by nationality
EUR - Evropská akce
UT code for WoS article
—