All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Case study of two domestic hot water storage concepts in residential heat pump systems

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F26%3A0201667" target="_blank" >RIV/00216305:26110/26:0201667 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.3390/buildings16051034" target="_blank" >https://doi.org/10.3390/buildings16051034</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/buildings16051034" target="_blank" >10.3390/buildings16051034</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Case study of two domestic hot water storage concepts in residential heat pump systems

  • Original language description

    This case study presents a comparative analysis of real-world operation two residential domestic hot water (DHW) preparation methods both connected to their own air-to-water heat pump (HP) located in Central Europe. One system employs a conventional configuration with separate tanks and an internal heating coil (HP-B), while the other features a compact tank-in-tank setup where DHW is heated via an integrated buffer tank (HP-A). Both systems were monitored under real operational conditions, with seasonal and annual coefficients of performance (COP, SCOP) calculated to evaluate efficiency. In the absence of complete thermal output data for one system, a reconstruction method based on the other’s performance and known heat losses was applied. The findings confirm that DHW system design significantly affects seasonal efficiency, particularly during summer operation when heating DHW dominates the energy load. The energy cost savings on heating during summer months could reach 44 %. The tank-in-tank system showed higher electrical consumption and lower SCOP due to internal heat transfer dynamics and dual-function operation. The study further shows associated energy and cost differences and demonstrates a practical approach to comparing real-world systems offering insights for design optimization and operational strategy. The authors of the article used the results of their research and experience from implementations as very effective feedback for further research and development. The novelty and uniqueness of the article lie in the energy comparison of two different connections of the hot water and heating water storage tanks with heat source systems using an “air-to-water” heat pump. The benefit of the solution in question is evident from the technical and economic evaluation.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20101 - Civil engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2026

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Buildings

  • ISSN

  • e-ISSN

    2075-5309

  • Volume of the periodical

    16

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    28

  • Pages from-to

  • UT code for WoS article

    001713708000001

  • EID of the result in the Scopus database