Peak-off-peak load shifting for optimal storage sizing in hybrid power systems using Power Pinch Analysis considering energy losses
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F18%3APU129909" target="_blank" >RIV/00216305:26210/18:PU129909 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.energy.2018.05.020" target="_blank" >http://dx.doi.org/10.1016/j.energy.2018.05.020</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.energy.2018.05.020" target="_blank" >10.1016/j.energy.2018.05.020</a>
Alternative languages
Result language
angličtina
Original language name
Peak-off-peak load shifting for optimal storage sizing in hybrid power systems using Power Pinch Analysis considering energy losses
Original language description
The difference in electricity pricing based on the time of power use has led to load shifting from peak to off-peak hours in hybrid power systems (HPS). Apart from optimising electricity cost, shifting of the load may also change the capacity of storage in the system. Power Pinch Analysis has been recently applied to guide load shifting aiming to minimise the cost of electricity, considering the peak and off-peak electricity pricing. The HPS was assumed to be ideal with 100% efficiency, which is not achievable in actual operational condition. This work extends the study by scrutinising the effects of peak-off-peak load shifting on the capacity of storage in HPS. The effects of energy losses due to the inefficiency during power conversion, transfer and storage in the HPS are considered in developing shifting heuristics to ensure optimal storage size is achieved. Implementation of the proposed load shifting strategy on a case study demonstrates that a reduction of up to 30% in the storage size can be achieved, which led to a minimum storage cost. The distribution of peak hours’ demand to off-peak hours also successfully provide significant savings in the electricity bill.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20402 - Chemical process engineering
Result continuities
Project
<a href="/en/project/EF15_003%2F0000456" target="_blank" >EF15_003/0000456: Sustainable Process Integration Laboratory (SPIL)</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Energy
ISSN
0360-5442
e-ISSN
1873-6785
Volume of the periodical
156
Issue of the periodical within the volume
156
Country of publishing house
GB - UNITED KINGDOM
Number of pages
12
Pages from-to
299-310
UT code for WoS article
000437073600025
EID of the result in the Scopus database
2-s2.0-85051383787