Design of Robust Total Site Heat Recovery Loops via Monte Carlo Simulation

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F19%3APU134503" target="_blank" >RIV/00216305:26210/19:PU134503 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.mdpi.com/1996-1073/12/5/930" target="_blank" >https://www.mdpi.com/1996-1073/12/5/930</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/en12050930" target="_blank" >10.3390/en12050930</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Design of Robust Total Site Heat Recovery Loops via Monte Carlo Simulation

  • Original language description

    For increased total site heat integration, the optimal sizing and robust operation of a heat recovery loop (HRL) are prerequisites for economic efficiency. However, sizing based on one representative time series, not considering the variability of process streams due to their discontinuous operation, often leads to oversizing. The sensitive evaluation of the performance of an HRL by Monte Carlo (MC) simulation requires sufficient historical data and performance models. Stochastic time series are generated by distribution functions of measured data. With these inputs, one can then model and reliably assess the benefits of installing a new HRL. A key element of the HRL is a stratified heat storage tank. Validation tests of a stratified tank (ST) showed sufficient accuracy with acceptable simulation time for the variable layer height (VLH) multi-node (MN) modelling approach. The results of the MC simulation of the HRL system show only minor yield losses in terms of heat recovery rate (HRR) for smaller tanks. In this way, costs due to oversizing equipment can be reduced by better understanding the energy-capital trade-off.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20402 - Chemical process engineering

Result continuities

  • Project

    <a href="/en/project/EF15_003%2F0000456" target="_blank" >EF15_003/0000456: Sustainable Process Integration Laboratory (SPIL)</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    ENERGIES

  • ISSN

    1996-1073

  • e-ISSN

  • Volume of the periodical

    5

  • Issue of the periodical within the volume

    12

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    10

  • Pages from-to

    930-940

  • UT code for WoS article

    000462646700163

  • EID of the result in the Scopus database

    2-s2.0-85063047468