Evaluation of a Stratified Tank based Heat Recovery Loop via Dynamic Simulation

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F18%3APU130598" target="_blank" >RIV/00216305:26210/18:PU130598 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.3303/CET1870068" target="_blank" >http://dx.doi.org/10.3303/CET1870068</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3303/CET1870068" target="_blank" >10.3303/CET1870068</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Evaluation of a Stratified Tank based Heat Recovery Loop via Dynamic Simulation

  • Original language description

    Prerequisite for hot water recovery in the dairy and beverage industry is the use of heat storage, such as stratified tanks. Total Site Heat Integration enables the targeting of heat recovery potential, the concrete identification of suitable sinks and source profiles and the dimensioning of intermediate circuits and storages. For a cost and energy efficient storage, the aim to maintain stratification by suitable thermocline control management. Dynamic simulation enables a reliable estimation of energy savings and correct storage/control design considering the changing operation times, source and sink loads as well as thermal inertias. This poses two challenges: model accuracy and acceptable simulation time. A stratified tank model with Variable Layer Height (VLH) is evolved reducing numeric diffusion effects. A sensitive analysis shows the increased accuracy with acceptable simulation time. As part of a case study, thermocline growth due to numeric diffusion is reduced up to approximately 35 % by a VLH model. The model is simulated for a case study in the dairy industry. It is shown that up to 94 % of the total heat recovery target can be achieved by the modelled heat recovery loop based on a stratified tank and the applied system control.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20402 - Chemical process engineering

Result continuities

  • Project

    <a href="/en/project/EF15_003%2F0000456" target="_blank" >EF15_003/0000456: Sustainable Process Integration Laboratory (SPIL)</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Chemical Engineering Transactions

  • ISBN

    978-88-95608-67-9

  • ISSN

    2283-9216

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    403-408

  • Publisher name

    Italian Association of Chemical Engineering - AIDIC

  • Place of publication

    Neuveden

  • Event location

    Prague

  • Event date

    Aug 25, 2018

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article