Fouling of Polymeric Hollow Fiber Heat Exchangers by Air Dust
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F20%3APU137825" target="_blank" >RIV/00216305:26210/20:PU137825 - isvavai.cz</a>
Result on the web
<a href="https://www.mdpi.com/1996-1944/13/21/4931" target="_blank" >https://www.mdpi.com/1996-1944/13/21/4931</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/ma13214931" target="_blank" >10.3390/ma13214931</a>
Alternative languages
Result language
angličtina
Original language name
Fouling of Polymeric Hollow Fiber Heat Exchangers by Air Dust
Original language description
Currently, liquid-to-gas heat exchangers in buildings, domestic appliances and the automotive industry are mainly made of copper and aluminum. Using plastic instead of metal can be very beneficial from an economic and environmental point of view. However, it is required that a successful plastic design meets all the requirements of metal heat exchangers. The polymeric hollow fiber heat exchanger studied in this work is completive to common metal finned heat exchangers. Due to its unique design (the use of thousands of thin-walled microtubes connected in parallel), it achieves a high level of compactness and thermal performance, low pressure drops and high operation pressure. This paper focuses on an important aspect of heat exchanger operation-its fouling in conditions relevant to building and domestic application. In heating, ventilation and air conditioning (HVAC) and automotive and domestic appliances, outdoor and domestic dust are the main source of fouling. In this study, a heat exchanger made of polymeric hollow fibers was tested in conditions typical for indoor HVAC equipment, namely with the 20 degrees C room air flowing through the hot water coil (water inlet 50 degrees C) with air velocity of 1.5 m/s. ASHRAE test dust was used as a foulant to model domestic dust. A polymeric heat exchanger with fibers with an outer diameter of 0.6 mm (1960 fibers arranged into 14 layers in total) and a heat transfer area of 0.89 m(2) was tested. It was proven that the smooth polypropylene surface of hollow fibers has a favorable antifouling characteristic. Fouling evolution on the metallic heat transfer surfaces of a similar surface density was about twice as quick as on the plastic one. The experimental results on the plastic heat exchanger showed a 38% decrease in the heat transfer rate and a 91% increase in pressure drops after eighteen days of the experiment when a total of 4000 g/m(2) of the test dust had been injected into the air duct. The decrease in the heat trans
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20303 - Thermodynamics
Result continuities
Project
<a href="/en/project/EF16_019%2F0000753" target="_blank" >EF16_019/0000753: Research centre for low-carbon energy technologies</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Materials
ISSN
1996-1944
e-ISSN
—
Volume of the periodical
13
Issue of the periodical within the volume
21
Country of publishing house
CH - SWITZERLAND
Number of pages
12
Pages from-to
1-12
UT code for WoS article
000589271800001
EID of the result in the Scopus database
2-s2.0-85095454087