Investigation on the thermal performance of flat-plate heat pipes with various working fluids under different inclination angles
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F22%3APU145043" target="_blank" >RIV/00216305:26210/22:PU145043 - isvavai.cz</a>
Result on the web
<a href="https://www-sciencedirect-com.ezproxy.lib.vutbr.cz/science/article/pii/S2352484722011763" target="_blank" >https://www-sciencedirect-com.ezproxy.lib.vutbr.cz/science/article/pii/S2352484722011763</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.egyr.2022.06.040" target="_blank" >10.1016/j.egyr.2022.06.040</a>
Alternative languages
Result language
angličtina
Original language name
Investigation on the thermal performance of flat-plate heat pipes with various working fluids under different inclination angles
Original language description
As one promising high-efficiency equipment, flat-plate heat pipes show an important influence on the thermal management of energy systems. This research experimentally investigates the effects of working fluids (acetone, ethanol, and 1.0 wt% Al2O3 water-based nanofluid), liquid filling ratios (30%, 45%, 60%, and 80%), and inclination angles (0°, 30°, 60°, and 90°) on thermal resistance and equivalent heat transfer coefficient of flat-plate heat pipes under input powers of 15 W, 30 W, 45 W, and 60 W. Results indicate that the flat-plate heat pipe with filling ratio of 60% has the minimum thermal resistance of 2.50 °C/W. Compared with filling ratios of 30%, 45%, and 80%, thermal resistance for 60% filling ratio decreases by 42.8%, 27.8%, and 50.7%. The thermal resistances for inclination angles of 0°, 30°, and 90° increase by 88.9%, 2.97%, and 11.8% compared to that with an inclination angle of 60°. The equivalent heat transfer coefficient of the flat-plate heat pipe increases by 90.8% when the inclination angle increases from 0° to 60° due to an effect of gravity. The heat transfer coefficient of the flat-plate heat pipe decreases by 7.2% when the inclination angle increases from 60° to 90°. The thermal resistance of the flat-plate heat pipe using Al2O3 nanofluid as the working medium decreases by 15.2% and 58.7% compared to those with acetone and ethanol. It is observed that partial dryout occurs when the input power is above 30 W. The evaporator with 5 cm length shows the best heat transfer performance of the flat-plate heat pipe.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20704 - Energy and fuels
Result continuities
Project
<a href="/en/project/EF15_003%2F0000456" target="_blank" >EF15_003/0000456: Sustainable Process Integration Laboratory (SPIL)</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Energy Reports
ISSN
2352-4847
e-ISSN
—
Volume of the periodical
neuveden
Issue of the periodical within the volume
8
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
10
Pages from-to
8017-8026
UT code for WoS article
000827278600008
EID of the result in the Scopus database
2-s2.0-85132927625