Mathematical modelling and model validation of the heat losses in district heating networks
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F23%3APU146612" target="_blank" >RIV/00216305:26210/23:PU146612 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0360544222033461#kwrds0010" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0360544222033461#kwrds0010</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.energy.2022.126460" target="_blank" >10.1016/j.energy.2022.126460</a>
Alternative languages
Result language
angličtina
Original language name
Mathematical modelling and model validation of the heat losses in district heating networks
Original language description
Today the most popular system of district heating systems is based on pre-insulated pipes arranged in parallel or twin-pipe configuration. One of the greatest difficulties with heat distribution through pipelines is thermal loss from the distribution. The most efficient solution to that problem is optimising the insulation wall thickness layer according to the pipe diameter. Heat losses should be minimised at a relatively low investment cost to find the most suitable insulation thickness economically. Numerous studies focus on analytical (1D model) calculations and numerical simulations. However, there is a research gap related to laboratory devices that allow measuring the operation parameters (fluid flow, the temperature of the fluid in the supply pipe and the return pipe). This paper presents an analysis of the heat losses from pre-insulated pipes and twin pipes in the heating system network. This study compares the heat losses in the ground calculated by analytical solution (1D model) with the measurements on the dedicated experimental setup. The calculations have been made for several heating network pipe variants: twin pipes: DN40, DN50, DN65, and their counterparts in a single parallel pre-insulated system. The insulation thickness used in all cases is 30.85 mm for DN40 and 32.00 mm for DN50 and DN65. The insulation is made of rigid polyurethane foam that meets the requirements of the PN-EN 253 standard. During the investigation, the thermal conductivity of insulation material is examined. The obtained thermal conductivity results are used in the calculations. The results from laboratory devices and analytical models have been compared, demonstrating good agreement – with a low error level in the range of approximately 8%, depending on the type of district heating pipe. The validated mathematical model of the heating network is then used to calculate the heat losses in a heating network connecting an underground storage tank with a ground source heat pump. Th
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20303 - Thermodynamics
Result continuities
Project
—
Continuities
R - Projekt Ramcoveho programu EK
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Energy
ISSN
0360-5442
e-ISSN
1873-6785
Volume of the periodical
267
Issue of the periodical within the volume
126460
Country of publishing house
GB - UNITED KINGDOM
Number of pages
4
Pages from-to
1-14
UT code for WoS article
000917290200001